Diagnostic performance of midupper arm circumference for detecting severe wasting among infants aged 1–6 months in Ethiopia

Author:

Jima Beshada R1ORCID,Hassen Hamid Y2,Getnet Yalemwork1,Bahwere Paluku3,Gebreyesus Seifu H1

Affiliation:

1. Department of Nutrition and Dietetics, School of Public Health, Addis Ababa University, Addis Ababa, Ethiopia

2. Department of Primary and Interdisciplinary Care, Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium

3. Centre of Research in Epidemiology, Biostatistics and Clinical Research, School of Public Health, Free University of Brussels, Brussels, Belgium

Abstract

ABSTRACT Background Midupper arm circumference (MUAC) is used as an independent diagnostic tool to detect wasting in children aged 6–59 mo. However, little is known about the diagnostic performance of MUAC for detecting wasting among infants aged 1–6 mo. Objective The objective of this study was to evaluate the diagnostic performance of MUAC in detecting severe wasting in infants aged 1–6 mo. Methods We conducted a facility-based cross-sectional study among 467 hospitalized infants aged 1–6 mo in Ethiopia. Severe wasting was defined as having a weight for length z score (WLZ) below the cutoff value of −3 SDs from the median as per the WHO 2006 child growth standards. Receiver operating characteristic (ROC) analysis along with the calibration test was used to test the discriminatory performance of MUAC. Furthermore, we calculated the sensitivity, specificity, positive predictive value, and negative predictive value for the proposed optimal cutoffs. Results The median age, MUAC, and WLZ were 100 d (IQR: 69–145 d), 119 mm (IQR: 103–130 mm), and −1.27 (IQR: −2.66 to 0.34), respectively. The prevalence of severe and moderate wasting was n = 101 (21.6%) and n = 61 (13.0%), respectively. The MUAC area under the ROC curve accuracy level in identifying severe wasting was 0.86 (95% CI: 0.82, 0.89). The optimal MUAC cutoff of ≤112 mm yielded the highest Youden index of 0.61, with a sensitivity of 85.1% (95% CI: 76.7%, 91.4%) and a specificity of 76.0% (95% CI: 71.2%, 80.2%). Conclusions A MUAC cutoff of ≤112 mm performed well in detecting severe wasting among infants aged 1–6 mo. Further research is needed to evaluate the performance of MUAC for detecting wasting at community level and for predicting mortality among infants aged <6 mo.

Funder

Addis Ababa University

Publisher

Oxford University Press (OUP)

Subject

Nutrition and Dietetics,Medicine (miscellaneous)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3