Use of Real Time Specimen Radiography to Evaluate the Number of Stereotactic Core Biopsy Specimens Containing Calcifications Required for Diagnosis

Author:

Kwait Dylan C1,Chikarmane Sona A1,Semine-Misbach Laura2,Agoston Agoston3,Lester Susan3,Giess Catherine S1

Affiliation:

1. Brigham and Women’s Hospital, Department of Radiology , Boston, MA , USA

2. Boston Medical Center, Department of Radiology , Boston, MA , USA

3. Brigham and Women’s Hospital, Department of Pathology , Boston, MA , USA

Abstract

Abstract Objective To determine the minimum number of stereotactic biopsy specimens containing calcifications sufficient for pathologic diagnosis and the minimum number of specimens containing calcifications sufficient for immunohistochemistry (IHC) in cases of malignancy. Methods In this IRB-exempt quality assurance initiative, individual specimens from 126 patients with 129 calcified targets retrieved using a stereotactic system with real time specimen imaging were prospectively analyzed. Pathology was reported independently for each specimen containing calcifications. In every case, the pathologist reported which specimen containing calcifications was sufficient for diagnosis and, in cases of malignancy, which calcified specimen was sufficient for diagnosis and IHC. Results A diagnosis was made from the first calcified specimen in 74% of cases (95/129), from the first two calcified specimens in 92% (119/129) of cases, and from the first three calcified specimens in 100% of cases. Pathology was benign in 66% (85/129) of cases, with the diagnosis made from the first calcified specimen in 78% (66/85) of cases. High-risk lesions were the primary pathology in 8% (11/129) of cases, with 55% (6/11) diagnosed from the first calcified specimen. Pathology was malignant in 26% (33/129) of cases. The first calcified specimen was sufficient for diagnosis and IHC in 73% (24/33) of malignancies and the first three calcified specimens were sufficient for diagnosis and IHC in all cases of malignancy. Conclusion Three cores verified to contain calcifications on real time specimen imaging were sufficient to make a diagnosis in all cases and to make a diagnosis and obtain IHC in nearly all cases of malignancy.

Publisher

Oxford University Press (OUP)

Subject

Radiology, Nuclear Medicine and imaging,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Breast Radiologists as Clinicians;Journal of Breast Imaging;2022-11-01

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3