Increasing power in screening trials by testing control-arm specimens: application to multicancer detection screening

Author:

Katki Hormuzd A1ORCID,Prorok Philip C2,Castle Philip E12ORCID,Minasian Lori M2,Pinsky Paul F2ORCID

Affiliation:

1. Division of Cancer Epidemiology and Genetics, Department of Health and Human Services, National Cancer Institute, National Institutes of Health , Bethesda, MD, USA

2. Division of Cancer Prevention, Department of Health and Human Services, National Cancer Institute, National Institutes of Health , Bethesda, MD, USA

Abstract

Abstract Background Cancer screening trials have required large sample sizes and long time-horizons to demonstrate cancer mortality reductions, the primary goal of cancer screening. We examine assumptions and potential power gains from exploiting information from testing control-arm specimens, which we call the “intended effect” (IE) analysis that we explain in detail herein. The IE analysis is particularly suited to tests that can be conducted on stored specimens in the control arm, such as stored blood for multicancer detection (MCD) tests. Methods We simulated hypothetical MCD screening trials to compare power and sample size for the standard vs IE analysis. Under two assumptions that we detail herein, we projected the IE analysis for 3 existing screening trials (National Lung Screening Trial [NLST], Minnesota Colon Cancer Control Study [MINN-FOBT-A], and Prostate, Lung, Colorectal, Ovarian Cancer Screening Trial—colorectal component [PLCO-CRC]). Results Compared with the standard analysis for the 3 existing trials, the IE design could have reduced cancer-specific mortality P values 6-fold (NLST), 33-fold (MINN-FOBT-A), or 260 000-fold (PLCO-CRC) or, alternately, reduced sample size (90% power) by 25% (NLST), 47% (MINN-FOBT-A), or 63% (PLCO-CRC). For potential MCD trial designs requiring 100 000 subjects per arm to achieve 90% power for multicancer mortality for the standard analysis, the IE analysis achieves 90% power for only 37 500-50 000 per arm, depending on assumptions concerning control-arm test-positives. Conclusions Testing stored specimens in the control arm of screening trials to conduct the IE analysis could substantially increase power to reduce sample size or accelerate trials and could provide particularly strong power gains for MCD tests.

Funder

National Institutes of Health

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3