Abstract

Abstract Health-care workers, laboratorians and overdose prevention centers rely on commercial immunoassays to detect the presence of fentanyl; however, the cross-reactivity of fentanyl analogs with these kits is largely unknown. To address this, we conducted a pilot study evaluating the detection of 30 fentanyl analogs and metabolites by 19 commercially available kits (9 lateral flow assays, 7 heterogeneous immunoassays and 3 homogenous immunoassays). The analogs selected for analysis were compiled from the Drug Enforcement Administration and National Forensic Laboratory Information System reports from 2015 to 2018. In general, the immunoassays tested were able to detect their intended fentanyl analog and some closely related analogs, but more structurally diverse analogs, including 4-methoxy-butyryl fentanyl and 3-methylfentanyl, were not well detected. Carfentanil was only detected by kits specifically designed for its recognition. In general, analogs with group additions to the piperidine, or bulky rings or long alkyl chain modifications in the N-aryl or alkyl amide regions, were poorly detected compared to other types of modifications. This preliminary information is useful for screening diagnostic, forensic and unknown powder samples for the presence of fentanyl analogs and guiding future testing improvements.

Funder

CDC

National Center for Injury Prevention and Control

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

Reference21 articles.

1. Fentanyl: a review for clinical and analytical toxicologists;Poklis;Journal of Toxicology Clinical Toxicology,1995

2. Fentanyl-related deaths in Ontario, Canada: toxicological findings and circumstances of death in 112 cases (2002–2004);Martin;Journal of Analytical Toxicology,2006

3. Control of immediate precursor used in the illicit manufacture of fentanyl as a schedule II controlled substance. Final rule;Drug Enforcement Administration (DEA), Department of Justice;Federal Register,2010

4. Drug and opioid-involved overdose deaths—United States, 2017–2018;Wilson;MMWR Morbidity and Mortality Weekly Report,2020

5. Notes from the field: opioid-involved overdose deaths with fentanyl or fentanyl analogs detected—28 states and the District of Columbia, July 2016–December 2018;O’Donnell;MMWR Morbidity and Mortality Weekly Report,2020