Importance of Preanalytical Factors in Measuring Cr and Co Levels in Human Whole Blood: Contamination Control, Proper Sample Collection and Long-Term Storage Stability

Author:

Sommer Yuliya L1,Ward Cynthia D1,Georgi Joaudimir Castro1,Cheng Po-Yung1,Jones Robert L1

Affiliation:

1. Centers for Disease Control and Prevention, National Center for Environmental Health, Division of Laboratory Sciences, Inorganic and Radiation Analytical Toxicology Branch, 4770 Buford Highway NE, Atlanta, GA 30341, USA

Abstract

Abstract A number of errors with potentially significant consequences may be introduced at various points in the analytical process, which result in skewed, erroneous analytical results. Precautionary procedures such as contamination control, following established sample collection protocols, and having a complete understanding of the long-term stability of the elements of interest can minimize or eliminate these errors. Contamination control is critical in the quantification of Cr and Co in human whole blood. Cr and Co levels in most biological samples are low, but these elements occur naturally in the environment and are often found in commercial and consumer products, which increases the risk of contamination. In this paper, we demonstrated that lot screening process in which we pre-screen a sub-set of manufactured lots used in collecting, analyzing and storing blood samples is a critical step in controlling Cr and Co contamination. Stainless steel needles are often utilized in blood collection but are considered as a potential source of introducing metal contamination to the patient sample. We conducted two studies to determine if there is a possibility of Cr or Co leaching into the human whole blood from the needles during blood collection. We analyzed blood collected from 100 donors and blood collected in vitro in the laboratory from designated vessel containing spiked blood with higher levels of Cr and Co. Two blood tubes were consecutively collected through one needle. In both studies, Cr and Co concentration levels in the two consecutively collected tubes were compared. Based on the results from donor and in vitro blood collection studies, we concluded that there was no Cr and Co leaching from the limited sets of stainless steel needles used in these studies. Furthermore, we demonstrated that Cr and Co human whole blood samples are stable for 1 year stored at temperatures of −70, −20 and 4°C and 6 months at room temperature.

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3