Consumption of the Sugar Substitute Stevia Leads to Cross-Reactivity of CEDIA® Buprenorphine II Immunoassay

Author:

Plattner Sabine,Pavlic Marion1,Pitterl Florian1,Schubert Birthe1

Affiliation:

1. Institute of Legal Medicine, Medical University of Innsbruck, Muellerstr. 44, 6020 Innsbruck, Austria

Abstract

Abstract Buprenorphine is a semisynthetic opioid that is often used in opiate maintenance therapy. For this purpose, regular toxicological analyses of urine samples are mandatory. For fast analytical results, analyses are commonly performed by immunoassay, for example, Thermo Scientific™ CEDIA® Buprenorphine or Buprenorphine II assay. One drawback of immunoassay-based methods is the possible cross-reaction with other substances. Several drugs have already been checked for cross-reactivity to CEDIA® Buprenorphine II immunoassay. In contrast, cross-reactivities have not been checked for any food additives. In the present study, a cross-reaction of CEDIA® Buprenorphine II assay to steviol glucuronide was investigated. Steviol glucuronide is a phase II metabolite of the sugar substitute stevia. For our study, 32 urine samples of patients in rehabilitation centers were collected. These samples were tested positive with the CEDIA® Buprenorphine II immunoassay. These findings were suspicious, because it was highly unlikely that the patients in those institutions had access to buprenorphine. The absence or presence of buprenorphine in urine samples was evaluated by a validated gas chromatography–mass spectrometry method. In order to determine the concentration of steviol glucuronide in urine samples, a liquid chromatography–tandem mass spectrometry method has been developed and fully validated according to the respective guidelines of the German Society of Toxicological and Forensic Chemistry. The cross-reactivity of steviol glucuronide in the CEDIA® Buprenorphine II immunoassay was observed at concentrations above 15,000 µg/L. These findings demonstrate that food additives should also be considered as compounds that may reduce the selectivity of immunoassays and emphasize the importance of confirming implausible results by selective analytical methods.

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3