Abstract

Abstract The application of Quantitative Structure–Property Relationship (QSPR) modeling to the prediction of reversed-phase liquid chromatography retention behavior of synthetic cannabinoids (SC), and its use in aiding the untargeted identification of unknown SC are described in this paper. 1D, 2D molecular descriptors and fingerprints of 105 SC were calculated with PaDEL-Descriptor, selected with Boruta algorithm in R environment, and used to build-up a multiple linear regression model able to predict retention times, relative to JWH-018 N-pentanoic acid-d5 as internal standard, under the following conditions: Agilent ZORBAX Eclipse Plus C18 (100 mm × 2.1 mm I.D., 1.8 μm) column with Phenomenex SecurityGuard Ultra cartridge (C18, 10 mm × 2.1 mm I.D., < 2 μm) kept at 50°C; gradient elution with 5-mM ammonium formate buffer (pH 4 with formic acid) and acetonitrile with 0.01% formic acid, flow rate 0.5 mL/min. The model was validated by repeated k-fold cross-validation using two-thirds of the compounds as training set and one-third as test set (Q2 0.8593; root mean squared error, 0.087, ca. 0.56 min; mean absolute error, 0.060) and by predicting relative Retention Times (rRT) of 5 SC left completely out of the modeling study. Application of the model in routine work showed its capacity to discriminate isomers, to identify unexpected SC in combination with mass spectral information, and to reduce the length of the list of candidate isomers to ca. one-third, thus reducing significantly the time required for predicting high-resolution product ion spectra to be compared to the unknown using a computational Mass Spectrometry (MS) search/identification approach.

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3