LC–QTOF-MS Presumptive Identification of Synthetic Cannabinoids without Reference Chromatographic Retention/Mass Spectral Information. II. Evaluation of a Computational Approach for Predicting and Identifying Unknown High-Resolution Product Ion Mass Spectra

Author:

Polettini Aldo E12,Kutzler Johannes2,Sauer Christoph2,Guber Susanne2,Schultis Wolfgang2

Affiliation:

1. Department of Diagnostics & Public Health, University of Verona, 371334 Verona, Italy

2. Department of Toxicology and Forensic Toxicology, Synlab MVZ Weiden GmbH, 92637 Weiden, Germany

Abstract

Abstract Despite liquid chromatography–high-resolution tandem mass spectrometry (MS2) enables untargeted acquisition, data processing in toxicological screenings is almost invariably performed in targeted mode. We developed a computational approach based on open source chemometrics software that, starting from a suspected synthetic cannabinoid (SC) determined formula, searches for isomers in different new psychoactive substances web databases, predicts retention time (RT) and high-resolution MS2 spectrum, and compares them with the unknown providing a rank-ordered candidates list. R was applied on 105 SC measured data to develop and validate a multiple linear regression quantitative structure–activity relationship model predicting RT. Competitive Fragmentation Modeling for Metabolite Identification (CFM-ID) freeware was used to predict/compare spectra with Jaccard similarity index. Data-dependent acquisition was performed with an Agilent Infinity 1290 LC-6550 iFunnel Q-TOF MS with ZORBAX Eclipse-Plus C18 (100 × 2.1 mm2/1.8 µm) in water/acetonitrile/ammonium formate gradient. Ability of the combined RT/MS2 prediction to identify unknowns was evaluated on SC standards (with leave-one-out from the RT model) and on unexpected SC encountered in real cases. RT prediction reduced the number of isomers retrieved from a group of new psychoactive substances web databases to one-third (2,792 ± 3,358→845 ± 983) and differentiated between SC isomers when spectra were not selective (4F-MDMB-BUTINACA, 4F-MDMB-BUTINACA 2ʹ-indazole isomer) or unavailable (4CN-Cumyl-B7AICA, 4CN-Cumyl-BUTINACA). When comparing 30/40 eV measured spectra of 99 SC against RT-selected, CFM-ID predicted spectra of isomers, the right candidate ranked 1st on median and 4th on average; 54% and 88% of times the right match ranked 1st or within the first 5 matches, respectively. To our knowledge, this is the first case of extensive chemometrics application to toxicological screening. In most cases, presumptive identification (being based on computation, it requires further information for confirmation) of unexpected SC was achieved without reference measured information. This method is currently the closest possible to true unbiased/untargeted screening. The bottleneck of the method is the processing time required to predict mass spectra (ca. 30–35 s/compound using a 64-bit 2.50-GHz Intel® Core™ i5-7200U CPU). However, strategies can be implemented to reduce prediction processing time.

Publisher

Oxford University Press (OUP)

Subject

Chemical Health and Safety,Health, Toxicology and Mutagenesis,Toxicology,Environmental Chemistry,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3