Poly-ether-ether-ketone (PEEK) versus dead-soft coaxial bonded retainers: a randomized clinical trial. Part 1. Stability, retainer failure, and participant satisfaction

Author:

Jasim Esraa Salman1ORCID,Kadhum Ammar Salim1ORCID

Affiliation:

1. Department of Orthodontics, College of Dentistry, University of Baghdad , Bab Al Muadham, Baghdad , Iraq

Abstract

Abstract Background Poly-ether-ether-ketone (PEEK) was introduced in dentistry as an alternative to metal alloys. Objective To assess the effectiveness of PEEK-fixed retainers in preserving the stability of mandibular anterior and participant satisfaction as compared to the Dead-soft coaxial fixed retainer (DSC). Trial design A single-centre, two-arm parallel groups randomized clinical trial. Methods The patients treated with pre-adjusted orthodontic appliances who have a Little’s Irregularity Index (LII) ≤ 0.5 mm have been enrolled in the trial. PEEK retainers were prepared to round 0.8 mm wire by computer-aided design and manufacturing, and the DSC wire was carefully adapted to the lingual surface of the lower anterior teeth. The primary outcome was the stability of lower anterior teeth as assessed by LII, while the secondary outcomes were changes in occlusal parameters, retainer failure, and patient satisfaction. The data were collected at the debonding stage (T0), 1 month (T1), 3 months (T3), and 6 months (T6) after starting the trial, except for patient’s satisfaction, which was recorded using an electronic form at T1 and T6. Blinding Single blinding of participants. Results A total of 46 participants with an age range of 12–28 years old were randomly allocated to the two groups (n = 23 in each). Only one participant dropped out; therefore, 45 participants were analysed. The DSC group showed a significant increase in LII at T3. Both retainer groups had comparable occlusal measurements, failure frequency, and survival time, with no significant difference. The patients in the DSC group reported a statistically significant perception of change in the position of their teeth compared to those in the PEEK group. Harms No harmful effects have been reported. Limitations Limited follow-up duration and the inability to blind the operator due to the nature of the intervention. Conclusions After 6-month retention, the PEEK retainer was equally effective to DSC retainers in maintaining the teeth alignment, with no significant differences regarding the failure frequency, survival rate, and general patient satisfaction. Trial registration https://register.clinicaltrials.gov. (NCT05557136).

Publisher

Oxford University Press (OUP)

Reference49 articles.

1. Toward a perspective on orthodontic retention;Melrose;American Journal of Orthodontics and Dentofacial Orthopedics,1998

2. Glass fibre reinforced versus multistranded bonded orthodontic retainers: a 2 year prospective multi-centre study;Tacken;European Journal of Orthodontics,2010

3. The bonded lingual retainer and multiple spacing of anterior teeth;Zachrisson;Journal of Clinical Orthodontics,1983

4. Bonded orthodontic retainers: a review;Bearn;American Journal of Orthodontics and Dentofacial Orthopedics,1995

5. Long-term effectiveness of canine-to-canine bonded flexible spiral wire lingual retainers;Renkema;American Journal of Orthodontics and Dentofacial Orthopedics,2011

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3