Liquid Chromatographic Determination of Pesticides in Finished Drinking Waters: Collaborative Study

Author:

Edgell Kenneth W1,Erb Elizabeth J1,Longbottom James E2,Lopez-Avila Vlorica3

Affiliation:

1. Bionetics Corporation, 16 Triangle Park Dr., Cincinnati, OH 45246

2. U.S. Environmental Protection Agency, 26 W. Martin Luther King Dr., Cincinnati, OH 45268

3. Mid-Pacific Environmental Laboratory, 625 B Clyde Ave, Mountain View, CA 94043

Abstract

Abstract A joint U.S. Environmental Protection Agency (EPA)/AOAC International collaborative study was conducted on EPA National Pesticide Survey Method 4, Determination of Pesticides in Finished Drinking Water by High Performance Liquid Chromatography with an Ultraviolet Detector, to determine mean recovery and precision for analyses of 18 pesticides and metabolites in reagent water and finished drinking waters. The study design was based on Youden's nonreplicate plan for collaborative studies of analytical methods. The waters were spiked with 18 pesticides and metabolites at 6 concentration levels, prepared as 3 Youden pairs. Ten volunteer laboratories extracted the spiked test waters with methylene chloride, performed a solvent exchange with methanol, and analyzed an aliquot of each extract by liquid chromatography using an ultraviolet detector at 254 nm. Results were analyzed using an EPA computer program that calculated recovery and precision for each of the 18 compounds and compared method performance between water types. The method was judged useable for all analytes tested. Recoveries were good for 16 of the analytes. The method exhibited poor recovery but acceptable between-laboratory precision for metribuzin DADK and metribuzin DK. The method performance statistics for carbofuran phenol and linuron were calculated to be significantly different for reagent water and finished drinking water. Similar statistical differences were observedfor metribuzin DADK, but these effects were not considered of practical significance due to the poor recovery (<25%) in both waters. In reagent water, the overall relative standard deviation (RSDR) range was 7.8-24.1% for all 18 compounds and 5.5-38.6% in finished drinking water. The single- analyst relative standard deviations (RSDr) range was 5.7-17.6% in reagent water and 4.0- 18.7% in finished drinking water. The method has been adopted first action by AOAC International.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3