Affiliation:
1. Department of Physical Medicine and Rehabilitation, Western University , London, ON N6C 0A7, Canada
2. Parkwood Institute Research, Lawson Health Research Institute , London, ON N6C 0A7, Canada
3. Division of Anatomy, Department of Surgery, University of Toronto , Toronto, ON M5S 1A8, Canada
Abstract
Abstract
Background
Lumbar medial branch radiofrequency ablation (RFA) is a common intervention to manage chronic axial low back pain originating from the facet joints. A more parasagittal approach targeting the posterior half of the lateral neck of superior articular process (SAP) was previously proposed. However, specific needle angles to achieve parallel placement at this target site have not been investigated.
Objective
To quantify and compare the needle angles, on posterior and lateral views, to achieve parallel placement of electrodes along the medial branch at the posterior half of the lateral neck of SAP at each lumbar vertebral level (L1–L5) and sacrum.
Design
Osteological Study
Methods
Twelve disarticulated lumbosacral spines (n = 72 individual bones) were used in this study. Needles were placed along the periosteum of the posterior half of the lateral neck of SAP, bilaterally and photographed. Mean needle angles for each vertebral level (L1–L5) and sacrum were quantified, and statistical differences were analyzed.
Results
The posterior view provided the degrees of lateral displacement from the parasagittal plane (abduction angle), while the lateral view provided the degrees of declination (cranial-to-caudal angle) of the needle. Mean needle angles at each level varied, ranging from 5.63 ± 5.76° to 14.50 ± 14.24° (abduction angle, posterior view) and 40.17 ± 7.32° to 64.10 ± 9.73° (cranial-to-caudal angle, lateral view). In posterior view, a < 10-degree needle angle interval was most frequently identified (57.0% of needle placements). In lateral view, the 40–50-degree (L1–L2), 50–60-degree (L3–L5), and 60–70-degree (sacrum) needle angle intervals occurred most frequently (54.2%, 50.0%, and 41.7% of needle placements, respectively).
Conclusions
Targeting the posterior half of the lateral neck of SAP required <10-degree angulation from parasagittal plane in majority of cases. However, variability of needle angles suggests a standard “one-size-fits-all” approach may not be the optimal technique.