Analytical Study of Comprehensive and Targeted Multidimensional Gas Chromatography Incorporating Modulated Cryogenic Trapping

Author:

Truong Thy T1,Marriott Philip J1,Porter Nichola A1

Affiliation:

1. Royal Melbourne Institute of Technology, Department of Applied Chemistry, GPO Box 2476V, Melbourne, Victoria 3001, Australia

Abstract

Abstract This paper reports the results of an analytical study comparing capillary gas chromatography (GC) operated in the normal mode with 2 new GC techniques, comprehensive GC (GC × GC) and targeted (or selective) multidimensional GC, which use a longitudinally modulated cryogenic system (LMCS), recently developed in our laboratory. A high-temperature application of derivatized sterols, of interest in fecal pollution monitoring, was chosen for this work. A directly connected coupled-column ensemble was used, comprising a nonpolar column and a moderately polar column. With LMCS, effluent from the first column is zone-compressed in a cryogenic trap and then pulsed to a short second column, producing narrower peaks with sharp, tall peak responses at the detector. The modulator is operated at a constant frequency, e.g., 0.25 s−1, to produce the GC × GC result, or is moved in a predefined manner so that whole peaks are selectively trapped and subsequently pulsed through to the second column in the targeted mode. Standard solutions containing a mixture of 7 sterols and 5-α-cholestane internal standard were used. Detection sensitivity is increased by a factor of ≥25 with the use of LMCS. The estimated limit of detection was about 0.1 μg/mL when normal GC with flame ionization detection (GC/FID) and a 1.0 μL splitless injection volume were used, compared with 0.02 and 0.004 μg/mL for the LMCS operated in GC × GC and selective modes, respectively. Calibration curves for GC/FID were linear over the 0.1–2.0 μg/mL range tested. Reproducibilities for the GC × GC and normal GC modes were comparable; generally, relative standard deviations (RSD) were on the order of 3–4%, based on raw peak responses. Improved reproducibility was found for selective LMCS operation, at an RSD of around 2%; with internal standardization, better results were achieved. The coupled-column arrangement allowed complete separation of sterol peaks from overlapping impurity peaks in a number of instances with LMCS modes, and its use should improve data quality over that of normal GC operation, in which the overlapping peaks interfere with measurement of peak response in the normal mode.

Publisher

Oxford University Press (OUP)

Subject

Pharmacology,Agronomy and Crop Science,Environmental Chemistry,Food Science,Analytical Chemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3