Influence of ultrafiltration conditions on the measurement of unbound drug concentrations: flucloxacillin as an example

Author:

Jager Nynke G L1ORCID,Van Ewijk-Beneken Kolmer Eleonora1,Aarnoutse Rob1,Te Brake Lindsey H M1

Affiliation:

1. Department of Pharmacy, Radboud Institute for Medical Innovation, Radboud University Medical Center , Nijmegen , The Netherlands

Abstract

Abstract Background When performing therapeutic drug monitoring (TDM) for flucloxacillin, it is advised to measure the unbound, not the total, flucloxacillin concentration. To be able to accurately quantify unbound flucloxacillin concentrations, a reliable analytical method is indispensable. Objective To determine the influence of temperature and pH of the sample during ultrafiltration on the measured unbound fraction of flucloxacillin. Materials and methods We performed three different experiments. In a single laboratory experiment, we investigated the influence of ultrafiltration temperature (10°C, room temperature and 37°C) on the measured unbound fraction of flucloxacillin for three concentration levels. In a multiple laboratory experiment, the results of eight laboratories participating in an international quality control programme measuring unbound flucloxacillin concentrations were analysed. In the third experiment, patient samples were ultrafiltrated using four different conditions: (i) physiological pH and room temperature; (ii) unadjusted pH (pH 9 after freezing) and room temperature; (iii) physiological pH and 37°C and (iv) unadjusted pH and 37°C. Results For all experiments, measurement of samples that were ultrafiltrated at room temperature resulted in a substantially lower unbound fraction compared to samples that were ultrafiltrated at 37°C. Adjusting the pH to physiological pH only had a minimal impact on the measured unbound fraction. Conclusions On the basis of these findings and considering the need for fast, simple and reproducible sample pretreatment for TDM purposes, we conclude that ultrafiltration of flucloxacillin should be performed at physiological temperature (37°C), but adjustment of pH does not seem to be necessary.

Funder

Dutch Foundation of Quality Assessment in Medical Laboratories

Drug Analysis and Toxicology

Publisher

Oxford University Press (OUP)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3