Automated Office Blood Pressure and the Impact of Attendance and Rest on Diagnostic Accuracy

Author:

Green Beverly B12ORCID,Anderson Melissa L1,Cook Andrea J1,Ehrlich Kelly1,Hall Yoshio N3,Margolis Karen L4,Thompson Matthew J5

Affiliation:

1. Kaiser Permanente Washington Health Research Institute , Seattle, Washington , USA

2. Washington Permanente Medical Group , Seattle, Washington , USA

3. Kidney Research Institute, University of Washington, Department of Medicine , Seattle, Washington , USA

4. HealthPartners Institute , Bloomington, Minnesota , USA

5. University of Washington, Department of Family Medicine , Seattle, Washington , USA

Abstract

Abstract Background Automated office blood pressure (AOBP) using 3–5 measurements taken with an oscillometric device with or without an attendant in the room may decrease “white coat” effect. We evaluated the impact of the presence or absence of the attendant and rest on BP and diagnosis of hypertension. Methods We randomly assigned 133 adults aged 18–85 with high BP at baseline (≥140/90 mm Hg), no hypertensive diagnosis and no antihypertensive medications to either attended AOBP first, unattended second, or unattended AOBP first, attended second. Outcomes included within-person BP difference for attended vs. unattended measurements; 5 vs. 15 minutes of rest; and the diagnostic performance of AOBP compared with daytime automated blood pressure measurement (ABPM). Results We found no significant differences between attended and unattended AOBP (mean difference attended − unattended [95% confidence interval, CI], systolic 0.14 mm Hg [−0.78, 1.06]; diastolic 0.16 mm Hg [−0.45, 0.78]) or by rest time (mean difference 15 − 5 minutes [95% CI], systolic −0.45 mm Hg [−1.36, 0.47]; diastolic 0.61 mm Hg [−1.23, 0.003]). AOBP was lower than mean daytime ABPM, regardless of attendance or rest (after 5 minutes rest systolic −3.6 and diastolic −2.55 mm Hg, P = 0.001 for both comparisons). Using daytime ABPM of ≥135/85 mm Hg as the diagnostic threshold, AOBP sensitivity and specificity after 5 minutes of rest were 71.0% and 54.1%, respectively. Conclusions The presence or absence of a clinic attendant during AOBP measurement and the amount of rest time before AOBP measurements had no effects on BP. AOBP measurements have low sensitivity and specificity for making a new diagnosis of hypertension.

Funder

Patient-Centered Outcomes Research Institute

Kaiser Permanente Washington Health Research Institute Development Fund

Publisher

Oxford University Press (OUP)

Subject

Internal Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3