RESULTS OF THE JOINT IAEA/ARPANSA INTERCOMPARISON EXERCISE ON WHOLE BODY DOSEMETERS FOR PHOTONS IN ASIA AND THE PACIFIC REGION

Author:

Rizk Chadia1ORCID,Long Stephen2,Okyar H Burçin3,Baradaran Samaneh4,Al Fares Elham5,Sangau John Konsoh6,Shah Buddha R7

Affiliation:

1. Lebanese Atomic Energy Commission, National Council for Scientific Research, PO Box 11-8281, Riad El Solh, Beirut 1107 2260, Lebanon

2. Australian Radiation Protection and Nuclear Safety Agency, 619 Lower Plenty Road, Yallambie, Victoria 3085, Australia

3. International Atomic Energy Agency, Vienna International Centre, PO Box 100, Vienna 1400, Austria

4. National Radiation Protection Department, Iranian Nuclear Regulatory Authority, Nuclear Science and Technology Research Institute, PO Box 14395-836, Av. Kargar Shomali, Tehran, Iran

5. Radiation Protection Department, Kuwait City, Al Sharq area, State of Kuwait

6. Malaysian Nuclear Agency, Ministry of Energy, Science, Technology, Environment & Climate Change, Bangi, 43000 Kajang, Selangor, Malaysia

7. Faculty of Science, Nepal Academy of Science and Technology, Khumaltar, Lalitpur, GPO 3323 Kathmandu, Nepal

Abstract

Abstract An intercomparison exercise (IC) on whole body dosemeters to determine the quantity personal dose equivalent Hp (10) in photon radiation fields was jointly organised and conducted by the International Atomic Energy Agency (IAEA) and the Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) for individual monitoring services (IMS) in Asia and the Pacific region. This was arranged to help the IMS in the region to achieve a more accurate dosimetry service and to improve their performance. Twenty-four IMS participated in this IC. Four sets of dosemeters were irradiated using X-ray and gamma radiation qualities at 0° and 20° angle of incidence, respectively. All the IMS provided results that were within the acceptable limits defined by the IAEA. However, only a minority of participants reported confidence intervals that included the reference dose, for each exposure scenario. For few systems, the overall performance could be significantly improved by reviewing calibration procedures.

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference18 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3