A WALK-IN TYPE CALIBRATION CHAMBER FACILITY FOR 222Rn MEASURING DEVICES AND INTER-COMPARISON EXERCISES

Author:

Trilochana S1,Somashekarappa H M1,Kumara K Sudeep1,Mohan M P1,Nayak S Rashmi1,D’Souza Renita Shiny1,Kamath Srinivas S1,Sahoo B K2,Gaware J J2,Sapra B K2,Janik M3,Al-Azmi Darwish4,Mayya Y S15,Karunakara N1ORCID

Affiliation:

1. Centre for Advanced Research in Environmental Radioactivity (CARER), Mangalore University, Mangalagangothri, Mangalore 574199, India

2. Radiological Physics and Advisory Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085, India

3. The National Institutes for Quantum and Radiological Science and Technology, Chiba, Japan

4. Department of Applied Sciences, College of Technological Studies, Public Authority for Applied Education and Training, Shuwaikh, PO Box 42325, Kuwait City 70654, Kuwait

5. Department of Chemical Engineering, IIT-Bombay, Mumbai 400 076, India

Abstract

Abstract A walk-in type 222Rn calibration chamber of volume 22.7 m3, which has traceability to international standards, is established at the Centre for Advanced Research in Environmental Radioactivity, Mangalore University, India. It has a human–machine interface communication system, a programmable logic controller and sensor feedback circuit for controlling and data acquisition of relative humidity (RH) and temperature (T). An innovative method for the generation of desired 222Rn concentration (a few hundred Bq m−3 up to about 36 kBq m−3) using soil gas as a source was adopted. Leak rates of 222Rn from the chamber for the mixing fan ON and OFF conditions were determined to be 0.0011 and 0.00018 h−1 respectively. With the exhaust system fully turned on, the maximum clearance rate of the chamber was 0.58 ± 0.07 h−1. Excellent spatial uniformity in 222Rn concentration in the chamber was confirmed (with a mean value of relative standard deviation < 12%) through measurements at 23 locations using CR-39 film-based passive devices. Demonstration of calibration applications was performed using charcoal canister and PicoRad vials as the 222Rn adsorption devices. The study shows that gamma spectrometry is a convenient alternative approach to liquid scintillation analysis of PicoRad vials for 222Rn measurement.

Funder

Board of Research in Nuclear Sciences

Publisher

Oxford University Press (OUP)

Subject

Public Health, Environmental and Occupational Health,Radiology, Nuclear Medicine and imaging,General Medicine,Radiation,Radiological and Ultrasound Technology

Reference44 articles.

1. Determination of radon, thoron and their progeny concentrations in dwellings of Gogi region, Yadgir District, Karnataka, India;Avinash;J. Environ. Radioact.,2014

2. Measurement of radon, thoron and their progeny in different types of dwelling in Almora district of Kumaun Himalayan region;Kuldeep;Radiat. Prot. Dosim.,2016

3. Radon/thoron and progeny levels in dwellings: Regional variations and effect of dwelling characteristics – A case study in Jalandhar district of Punjab, India;Manish;Indoor Built Environ.,2017

4. Dose estimation derived from the exposure to radon, thoron and their progeny in the indoor environment;Ramola;Sci. Rep.,2016

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3