Affiliation:
1. Department of Trauma & Orthopaedics, Ysbyty Gwynedd, Penrhosgarnedd, Bangor LL57 2PW, UK
Abstract
Abstract
Most studies regarding the use of locking condylar plates in distal femoral fractures have been carried out in tertiary centres. The aim of this case series was to examine outcomes for patients managed in a rural setting and to answer the question: ‘should we be shipping these patients out to a regional trauma centre?’ Recent insertions of condylar locking compression plates (LCPs) at a rural district general hospital were examined. (All used the Synthes LCP Condylar Plate 4.5/5.0 periarticular plating system). Their clinical records and radiology were reviewed to identify failure rates and facilitate discussion of such cases. Of 36 reviewed cases, 4 instances of failure were identified (11%), and their cases are discussed individually herein. This review not only affords the opportunity to discuss cases of failure and to speculate upon their potential causes, but also highlights reassuringly high quality of outcomes for these patients outside of larger teaching hospitals.
Publisher
Oxford University Press (OUP)
Reference18 articles.
1. The epidemiology of fractures of the distal femur;Martinet;Injury,2000
2. Treatment of acute distal femur fractures;Brett;Orthopedics,2008
3. Supracondylar fractures of the femur;Schatzker;Clin Orthop Relat Res,1979 -
4. Importance of the friction between the plate and the bone in the anchoring of plates for osteosynthesis. Determination of the coefficient of metal-bone friction in animals in vivo;Cordey;Helv Chir Acta,1979
5. The development of the distal femur less invasive stabilization system (LISS);Frigg;Injury,2001