The use of portable X-ray fluorescence spectrometry to measure apparent total tract digestibility in beef cattle and sheep

Author:

Hoffmann Carly A1,Sarturi Jhones O1,Weindorf David C2,Henry Darren D1,Ramirez- Ramirez Hugo A3,Jackson Samuel1,Ballou Michael A4,Sandes Michael D1,Bouyi Legrand1

Affiliation:

1. Department of Animal and Food Sciences, Texas Tech University, Lubbock, TX

2. Department of Plant and Soil Sciences, Texas Tech University, Lubbock, TX

3. Department of Animal Science, Iowa State University, Ames, IA

4. Department of Veterinary Sciences, Texas Tech University, Lubbock, TX

Abstract

Abstract The use of portable X-ray fluorescence (PXRF) spectrometry to detect external markers on processed or unprocessed cattle and sheep fecal specimens to estimate apparent total tract digestibility (ATTD) was evaluated. Exp. 1: ruminally cannulated Angus-crossbred steers (n = 7; BW = 520 ± 30 kg) were individually fed ad libitum for 21 d in a completely randomized design (CRD). Markers (Cr2O3 and TiO2) were placed inside the rumen twice daily (7.5 g of each marker). Fecal samples were collected twice daily from day 14 to 21. Exp. 2: crossbred wethers (n = 8; BW = 68 ± 3 kg) were individually fed ad libitum for 21 d in a CRD. During this period, 2 g of Cr2O3 and TiO2 were top-dressed onto the feed twice daily. Sheep were housed in metabolism crates for 5 d for total fecal collection. Concentration of markers was determined on diets, refusals, and fecal specimens (fresh, dry-only, and dried/ground) using atomic absorption to detect Cr and spectrophotometry for Ti. Concentration of both markers was also determined via the PXRF spectrometer. Delta between ATTD estimated by wet chemistry and PXRF was not different from zero (P ≥ 0.14) when using cattle fresh fecal specimens for both markers, whereas ATTD estimated by PXRF with dry-only and dried/ground fecal specimens were 3.6 and 1.1 percent units lower (P ≤ 0.04), respectively, than ATTD estimated by wet chemistry for Cr and Ti, respectively. Regardless of the fecal sample preparation method on cattle specimens, Ti concentration was similar (P = 0.39) among methodologies, while Cr was underestimated (P < 0.01) by 13% when PXRF was used in dry-only or dried/ground samples. The ATTD of sheep was underestimated (P < 0.01) by 2.4 percent units compared with control when Cr was measured by PXRF in dry-only samples. The Cr concentration in dry-only fecal specimens of sheep tended (P = 0.09) to be lower compared with wet chemistry analysis. Fresh and dry/ground sheep fecal samples assessed for Cr, and dry-only assessed for Ti were not (P ≥ 0.49) affected by detection method. The Cr fecal recovery tended (P = 0.10) to be the lowest for dry-only, the greatest for wet chemistry, intermediate for fresh and dry/ground sheep-fecal specimens; while not affected (P = 0.40) for Ti. The PXRF is an accurate technology to detect Cr and Ti in fresh cattle fecal samples to estimate ATTD. For fresh and dry/ground, the technology was effective for determining the concentration of Cr, or dry-only fecal specimens when detecting Ti in sheep specimens.

Funder

Houston Livestock Show & Rodeo

Publisher

Oxford University Press (OUP)

Subject

Genetics,Animal Science and Zoology,General Medicine,Food Science

Reference23 articles.

1. Using portable X-ray fluorescence (pXRF) to determine fecal concentrations of non-absorbable digesta kinetic and digestibility markers in sheep and cattle;Barnett;Anim. Feed Sci. Tech,2016

2. Estimation of apparent digestibility coefficients by means of an inert reference substance;Barnicoat;New Zealand Jour. Sci. Tech,1945

3. The use of markers to partition digestion within the gastro-intestinal tract of ruminants. In: CSIRO Division of Animal Physiology, Ian Clunies Ross Animal Research Laboratory, P.O. Box 239, Blacktown, NSW 2148, Australia., editor/s;Faichney,1974

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3