Comparison of assay methods for quantifying sex hormone concentrations across the menstrual cycle in rhesus macaques

Author:

Fecteau Kristopher M1,Winchell Andrea J1,Blue Steven W1,Appleman Maria Luisa2,Urbanski Henryk F23,Erikson David W1ORCID

Affiliation:

1. Endocrine Technologies Core, Oregon National Primate Research Center , Beaverton, OR , USA

2. Division of Neuroscience, Oregon National Primate Research Center , Beaverton, OR , USA

3. Division of Reproductive & Developmental Sciences, Oregon National Primate Research Center , Beaverton, OR , USA

Abstract

Abstract Immunoassays have been the preferred method for steroid hormone analysis for more than 50 years. Automated immunoassays (AIAs) offer high throughput, rapid data turnaround, and low cost for measuring steroid hormone concentrations. The application of liquid chromatography–tandem mass spectrometry (LC-MS/MS) for steroid quantification provides greater specificity and selectivity for individual steroids, the ability to simultaneously analyze multiple steroids, and high throughput and automation. We compared AIA and LC-MS/MS for analysis of 17beta-estradiol (E2) and progesterone (P4) over the course of several menstrual cycles in 12 rhesus macaques (Macaca mulatta). Serum samples were collected every 4 days across four menstrual cycles from each monkey. AIAs were performed on a Roche cobas e411 analyzer. LC-MS/MS analysis was performed on a Shimadzu-Nexera-LCMS-8060 instrument. Scatter plots with Passing–Bablok regression showed excellent agreement between AIA and LC-MS/MS for both E2 and P4. Bland–Altman plots revealed no bias for either method; however, AIA overestimated E2 at concentrations >140 pg/ml and underestimated P4 at concentrations >4 ng/ml compared to LC-MS/MS. A comparison of testosterone concentrations measured by AIA and LC-MS/MS in the same samples was also performed. In contrast to E2 and P4, AIA and LC-MS/MS yielded significantly different results for testosterone concentrations, with AIA consistently underestimating concentrations relative to those obtained by LC-MS/MS. Well-characterized automated immunoassays are an excellent tool for daily monitoring of monkey menstrual cycles or providing single data points requiring fast turnaround. In certain situations where AIAs may provide inaccurate estimations of E2 and P4 concentrations, LC-MS/MS assays are preferable.

Funder

NIH

Publisher

Oxford University Press (OUP)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3