Non-viral gene coating modified IOL delivering PDGFR-α shRNA interferes with the fibrogenic process to prevent posterior capsular opacification

Author:

Wang Jiahao1,Hu Yulin1,Han Yuemei1,Fang Qiuna1,Chen Zhirong1,Wang Yajia1,Zhao Peiyi1,Wang Hui1,Lin Quankui1ORCID

Affiliation:

1. Department of Biomaterials, National Engineering Research Center of Ophthalmology and Optometry, School of Biomedical Engineering, School of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University , Wenzhou 325027, China

Abstract

AbstractPosterior capsule opacification (PCO), the most common complication after cataract surgery, is caused by the proliferation, migration and epithelial–mesenchymal transition (EMT) of residual lens epithelial cells in the capsule bag. Although the surface modification and drug loading of intraocular lens (IOLs) have been effective in preventing PCO to some extent, the intraocular safety of anti-proliferative drug application is still a major limitation in clinical application. In this study, we used non-viral gene delivery systems in combination with layer-by-layer (LBL) self-assembly technology, and the modified IOL could effectively prevent the development of PCO by interfering with the EMT process mediated by the platelet-derived growth factor receptor-α (PDGFR-α). Herein, the gene fragments were wrapped by electrostatic conjugation using polyethyleneimine-graft-poly(ethylene glycol) to form gene complexes. Gene complexes were characterized by dynamic light scattering, transmission electron microscopy (TEM) and agarose gel electrophoresis, and evaluated for storage and serum stability. The layer assembly behavior of the IOL surface, changes in optical properties and the release behavior of the gene complexes were characterized using quartz crystal microbalance, UV–vis, contact angle and TEM. In vitro experiments showed that the IOL coating has good bio-compatibility and can achieve the corresponding transfection effect, and the released gene complexes exhibited excellent cell internalization and lysosomal escape behaviors, as well as effective inhibition of PDGFR-α expression and its mediated EMT process. The early PCO prevention effect and bio-compatibility evaluation of the modified IOL in vivo were evaluated by implantation into animal eyes. This study provides a new strategy for the development of surface modifications of small nucleic acid drugs and non-toxic EMT interference therapies for PCO.

Funder

Zhejiang Provincial Natural Science Foundation

Publisher

Oxford University Press (OUP)

Subject

Biomaterials

Reference69 articles.

1. The global state of cataract blindness;Lee;Curr Opin Ophthalmol,2017

2. Global causes of vision loss in 2015: Are we on track to achieve the vision 2020 target?;Sabanayagam;Lancet Glob Health,2017

3. Cataracts;Liu;Lancet,2017

4. Topical anaesthesia plus intracameral lidocaine versus topical anaesthesia alone for phacoemulsification cataract surgery in adults;Minakaran;Cochrane Database Syst Rev,2020

5. Drug-eluting intraocular lens with sustained bromfenac release for conquering posterior capsular opacification;Zhang;Bioact Mater,2022