Troponin T and I Assays Show Decreased Concentrations in Heparin Plasma Compared with Serum: Lower Recoveries in Early than in Late Phases of Myocardial Injury

Author:

Gerhardt Willie1,Nordin Gunnar1,Herbert Ann-Katrin1,Linåker Burzell Birgitta1,Isaksson Anders2,Gustavsson Elisabeth3,Haglund Sofie4,Müller-Bardorff Margit5,Katus Hugo A5

Affiliation:

1. Department of Clinical Chemistry, Lasarettet, S-251 87 Helsingborg, Sweden

2. Department of Clinical Chemistry, University Hospital Lund, 221 85 Lund, Sweden

3. Department of Clinical Chemistry, Karolinska Sjukhuset, 171 76 Stockholm, Sweden

4. Department of Clinical Chemistry and Transfusion Medicine, Ryhov, S-551 85 Jönköping, Sweden

5. Medizinische Klinik II, Medizinische Universität zu Lübeck, 23528 Lübeck, Germany

Abstract

AbstractBackground: Heparinized plasma samples allow more rapid analysis than serum samples, but preliminary studies showed lower cardiac troponin T (cTnT) results in plasma. We undertook a multicenter study to characterize this effect for cTnT and cardiac troponin I (cTnI).Methods: Blood samples were collected with and without heparin at five hospitals. cTnT was measured by a “third generation” assay (Elecsys®), and cTnI was measured by a commercial immunoassay (IMMULITE®).Results: Mean cTnT was 15% lower in heparin sampling tubes than in serum. Measured concentrations of cardiac troponins also decreased with increasing heparin concentrations added to sera. Heparin-induced losses were greater in early than in late phases after onset of chest pain. Addition of heparin (∼100 IU/mL) to serial samples from nine acute myocardial infarction patients produced mean cTnT losses of 33% at 1–12 h after onset of chest pain, 17% at 13–48 h, and 7% after 48 h. The changing heparin effects were seen for both cTnT and cTnI during time courses of individual patients with myocardial infarction.Conclusion: We suggest that binding of heparin to troponins decreases immunoreactivity, especially in early phases of myocardial injury. The resulting losses may depend on the antibodies used in each troponin assay.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3