Circulating Immunoreactive proANP(1-30) and proANP(31-67) in Sedentary Subjects and Athletes

Author:

De Palo Elio F1,Woloszczuk Wolfgang2,Meneghetti Martina1,De Palo Carlo B1,Nielsen Henning B3,Secher Niels H3

Affiliation:

1. Section of Clinical Biochemistry, Department of Medical Diagnostic Sciences and Special Therapy, University of Padua, 35100 Padua, Italy

2. Ludwig Boltzmann Institut für Experimentelle Endokrinologie, A-1100 Wien, Austria

3. Department of Anesthesia, University of Copenhagen, DK-2100 Copenhagen, Denmark

Abstract

Abstract Background: Atrial natriuretic peptide (ANP) is synthesized and stored in myocytes as prohormone(1-126), which upon release is cleaved into proANP(1-98) and α-ANP(99-126). In addition, cleavage of proANP(1-98) produces proANP(1-30), proANP(31-67), and proANP(79-98) fragments. ProANP(1-30) and proANP(31-67) have roles in fluid and electrolyte homeostasis. The aim of the present study was to develop a plasma assay for proANP(1-30) and proANP(31-67) and to compare results in trained athletes and sedentary subjects. Methods: Two competitive enzyme immunoassays were established with affinity-purified sheep antiserum against synthetic ANP fragments. The immunoreactivity (ir) of proANP(1-30) and proANP(31-67) was measured in 10-μL plasma samples without extraction in a microwell-based assay. Plasma concentrations in sedentary male subjects (n = 22) and male endurance athletes (n = 14) were examined. Results: In the assay for ir-proANP(1-30) and ir-proANP(31-67), the concentrations at 95% B/B0 were 4.7 and 14.2 pmol/L, respectively. Within-run CVs were 4–6% and 5–6%, and between-run CVs were 9% for both assays. Both assays were linear on dilution (y = 0.9945x − 0.7291 and y = 1.0001x − 3.428), and the recoveries were 102–112% and 102–106%, respectively. In the sedentary and athletic groups, the ir-proANP(1-30) concentrations were similar: 318 ± 38 pmol/L and 312 ± 25 pmol/L (mean ± SE), respectively, whereas the ir-proANP(31-67) was higher in the rowers (713 ± 81 pmol/L) than in the sedentary subjects (387 ± 71 pmol/L; P <0.005). Conclusions: The proANP fragment assays are precise (CV <10%) and exhibit nearly quantitative recovery (102–112%). Only ir-proANP(31-67) responds to physical training.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 29 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3