Comparison of analytical performance and biological variability of three bone resorption assays

Author:

Ju Hsin-Shan J,Leung Sunny,Brown Bradley1,Stringer Matthew A1,Leigh Scott2,Scherrer Christy,Shepard Karen,Jenkins Dean,Knudsen Jane,Cannon Robert

Affiliation:

1. Present address: Fusion Technologies, Inc., 1615 Plymouth St., Mountain View, CA 94043

2. Present address: Collagen Corp., 2500 Faber Pl., Palo Alto, CA 94303

Abstract

Abstract We have compared the analytical performance and biological variability of three commercially available bone resorption assays: Pyrilinks®-D, Osteomark®, and CrossLaps™, for the measurement of urinary free deoxypyridinoline (Dpd), cross-linked N-telopeptides of type I collagen (NTx), and linear C-telopeptides of type I collagen (CTx), respectively. The intraassay and interassay CVs for precision of the Dpd and NTx assays were <10% for analyte concentrations greater than the second calibrator (i.e., 3 nmol/L Dpd or 30 nmol bone collagen equivalents/L NTx). The CTx assay demonstrated poor precision for analyte concentration lower than the third calibrator (i.e., 200 μg/L). The NTx assay exhibited nonlinear recovery for sample dilutions prepared in buffer; however, this nonlinear recovery could be corrected for sample dilutions made in urine at a low analyte concentration. Supplement recoveries of each of the three assays were within 100% ± 10% on average. All three analytes showed stability through five freeze–thaw cycles. The mean day-to-day variations were 16% for Dpd, and 23% for both NTx and CTx. Similar diurnal rhythm was observed for all three assays on average, with the peak in the early morning and the nadir in the afternoon. Mean amplitude of the diurnal variation was 37% for Dpd and NTx, and 57% for CTx. Variations within the reference intervals for a healthy premenopausal population were 28% for Dpd, 57% for NTx, and 56% for CTx. Pyrilinks-D has demonstrated analytical precision and accuracy equal or superior to Osteomark and CrossLaps in all areas. Dpd exhibits the least biological variability day-to-day, within individuals across the diurnal cycle, and within a healthy premenopausal population.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 90 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370