Use of phenylalanine-to-tyrosine ratio determined by tandem mass spectrometry to improve newborn screening for phenylketonuria of early discharge specimens collected in the first 24 hours

Author:

Chace Donald H1,Sherwin John E2,Hillman Steven L3,Lorey Fred2,Cunningham George C2

Affiliation:

1. Neo Gen Screening, 110 Roessler Road, Pittsburgh, PA 15220

2. California Department of Health Services, Genetic Disease Branch, 2151 Berkeley Way, Annex 4, Berkeley, CA 94704

3. Division of Medical Genetics, Department of Pediatrics, Duke University Medical Center, Research Triangle Park, NC 27709

Abstract

Abstract We compared the screening interpretation of fluorometric analytical results for phenylketonuria (PKU) with tandem mass spectrometry (MS/MS) in filter paper blood spots collected from newborns <24 h of age. In MS/MS, both Phe and Tyr are quantified. Two hundred and eight blood spots collected from infants <24 h of age were retrieved from storage from the California newborn screening program. These samples had been categorized on the basis of fluorometric analysis as initial negative, initial positive for hyperphenylalaninemia with negative determination on recall, or initial positive for hyperphenylalaninemia and confirmed on follow up as PKU or variant hyperphenylalaninemia. The retrieved samples were analyzed in a blinded fashion using MS/MS. Correlation analysis of fluorometry vs MS/MS for Phe concentration was high, with a Pearson correlation coefficient of 0.817. When 180 μmol/L was used as the cutoff Phe concentration for MS/MS and 258 μmol/L was used as the cutoff for fluorometry, all infants with confirmed classical PKU and variant hyperphenylalaninemia were detected. MS/MS analysis reduced the number of false-positive results from 91 to 3. Simultaneous quantification of Phe and Tyr by MS/MS with the use of a cutoff Phe/Tyr molar ratio of 2.5 further reduced the number of false positives to 1. Samples from affected infants showed a discernible trend of increasing Phe concentration and Phe/Tyr molar ratio with age of collection. These results demonstrate the utility of MS/MS in the routine PKU screening of early-discharge newborns. MS/MS reduces the false-positive rate of fluorometric screening almost 100-fold because of the improved accuracy and precision of Phe measurement and simultaneous confirmation with the Phe/Tyr molar ratio. In addition to the detection of PKU, MS/MS can also detect other aminoacidopathies and disorders of fatty acid and organic acid metabolism with lower false-positive rates than other methods currently used in newborn screening programs.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 137 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3