Analytical and clinical evaluation of an electrochemiluminescence immunoassay for the determination of CA 125

Author:

van Ingen Huub E1,Chan Daniel W2,Hubl Walter3,Miyachi Hayato4,Molina Rafael5,Pitzel Lutz6,Ruibal Alvaro7,Rymer Jean C8,Domke Ingrid9

Affiliation:

1. Department of Clinical Chemistry, AZR Daniel den Hoed Cancer Center, Groene Hilledijk 301, 3075 EA Rotterdam, The Netherlands

2. Department of Pathology, Johns Hopkins Medical Institutions, Baltimore, MD 21205

3. Institut für Klinische Chemie, Krankenhaus Dresden Friedrichstadt, D-1067 Dresden, Germany

4. Department of Clinical Pathology, Toukai University School of Medicine, Isehara, Japan

5. Unitat de Recerca del Cancer, Hospital Clinic I Provincial, Barcelona E-08034, Spain

6. Abteilung für Klinische und Experimentelle Endokrinologie, Frauenklinik, Georg-August-Universitaet Goettingen, D-37075 Goettingen, Germany

7. Centro de Patologia de la Mama, E-28003 Madrid, Spain

8. Laboratoire Central de Biochimie, Hopital Henri Mondor, Creteil Cedex F-94010, France

9. Boehringer Mannheim GmbH, D-68305 Mannheim, Germany

Abstract

Abstract The CA 125 II assay on the Elecsys® 2010 analyzer was evaluated in an international multicenter trial. Imprecision studies yielded within-run CVs of 0.8–3.3% and between-day CVs of 2.4–10.9%; CVs for total imprecision in the manufacturer’s laboratory were 2.4–7.8%. The linear range of the assay extended to at least 4500 kilounits/L (three decades). Interference from triglycerides (10.3 mmol/L), bilirubin (850 μmol/L), hemoglobin (1.1 mmol/L), anticoagulants (plasma), and several widely used drugs was undetectable. Method comparisons with five other CA 125 II assays showed good correlation but differences in standardization. A 95th percentile cutoff value of 35 kilounits/L was calculated from values measured in 593 apparently healthy (pre- and postmenopausal) women. In 95% of patients with benign gynecological diseases CA 125 was ≤190 kilounits/L; 63% of patients with newly diagnosed ovarian carcinoma had values >190 kilounits/L. A comparison of CA 125 values obtained with the Elecsys test and with other common CA 125 tests in monitored patients being treated for ovarian cancer showed identical patterns. In conclusion, the Elecsys CA 125 II assay is linear over a broad range, yields precise and accurate results, is free from interferences, and compares well with other assays.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3