Quantitative nephelometric assay for determining myoglobin evaluated

Author:

Delanghe J R1,Chapelle J P1,Vanderschueren S C1

Affiliation:

1. Department of Clinical Chemistry, Universitair Ziekenhuis De Pintelaan, Gent, Belgium

Abstract

Abstract A recently introduced automated nephelometric immunoassay involving shell/core particles for determination of myoglobin (Behringwerke) was evaluated with the BNA Nephelometer. Method precision was good: the intra-assay CV varied between 1.5% and 6.1%; with daily calibration, the interassay CV ranged between 1.5% and 7.5%. For usual sample dilutions, the assay response varied linearly with myoglobin concentrations up to 23.1 nmol/L. After automatic dilution by the instrument, concentrations up to 2310 nmol/L could be measured without high-dose "hook" effect. Further manual dilution allowed measurement of myoglobin concentrations up to 26,000 nmol/L. Calibration was stable for at least seven days. We detected no significant interferences from hemoglobin, haptoglobin, bilirubin, iodine-containing contrast media, and rheumatoid factors. Treating lipemic samples with Lipoclean (Behringwerke) decreased test results. Simultaneously drawn serum and plasma samples from the same subject showed no consistent differences in myoglobin concentrations. The mean reference myoglobin concentration was 1.380 (SD 0.82) nmol/L for men and 0.878 (SD 0.45) nmol/L for women. In patients with renal insufficiency, serum creatinine values were moderately related to serum myoglobin values (r = 0.465). Although a commercial radioimmunoassay (Byk-Sangtec) and the nephelometric assay intercorrelated well (r = 0.929), values obtained by nephelometry were significantly lower (P less than 0.05). By both assays, results for heart and skeletal muscle tissue extracts showed no correlation, a finding that suggests the existence of multiple forms of myoglobin in human tissues. We conclude that immunonephelometry is a rapid, practical, and reliable method for measuring myoglobin in serum.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3