Affiliation:
1. Department of Obstetrics and Gynaecology, Gentofte University Hospital, Hellerup, Denmark
Abstract
Abstract
We examined three enzyme-linked immunosorbent assay (ELISA) kits for human choriogonadotropin (hCG) (pregnancy tests) for use with urine and serum samples: the Tandem Icon II hCG Urine and Tandem Icon II hCG Serum, the NovoClone Target hCG Test, and the Abbott TestPacks hCG-urine and hCG-serum. Paired comparison of the results from each kit indicated that the NovoClone Target assay showed significantly lower diagnostic sensitivity (P less than 0.05) than did the Tandem Icon II or Abbott TestPack, both for urine and for serum samples. None of the products demonstrated any significant difference (P greater than 0.05) in diagnostic specificity, but the NovoClone Target kit showed several serious false-negative results with both urine and serum. Paired testing of urine kits vs serum kits also showed no significant differences (P greater than 0.05) in diagnostic sensitivity or specificity. We found the Abbott kits to be the most convenient to use and to read.
Publisher
Oxford University Press (OUP)
Subject
Biochemistry (medical),Clinical Biochemistry
Cited by
11 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献