1. Laboratorio Calcolosi Renale, Ospedale Mauriziano Umberto I, Torino, Italy
Abstract
Abstract
In an attempt to decrease ascorbate interference on the ion-chromatographic determination of urinary oxalate, we compared the effectiveness of four different methods for ascorbate elimination by analyzing a representative urine pool supplemented with successive ascorbate additions. Two of the methods--treatment with ferric ions or boric acid--have been described elsewhere; treatments with nitrites or ascorbate oxidase (EC 1.10.3.3) are investigated here as possible alternatives. Consideration of the main features, advantages, and drawbacks of the four procedures leads us to conclude that boric acid dilution is a good routine method and that pre-incubation with ascorbate oxidase reliably prevents ascorbate interference in assays of urinary oxalate.
Publisher
Oxford University Press (OUP)
Subject
Biochemistry (medical),Clinical Biochemistry
Cited by
13 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献