Abstract

Abstract Background: Recently, measurement of very low concentrations of C-reactive protein (CRP) has gained popularity as a potential new means for predicting the risk of future cardiac complications. In this study, we demonstrate the feasibility of a kinetic, one-step microparticle assay for quantitative determination of extremely low and high CRP concentrations in the limited timeframe typical for point-of-care testing. Methods: A noncompetitive, kinetic CRP immunoassay was developed that uses individual, porous microparticles as the solid phase. The microparticles were covalently coated with a monoclonal capture antibody, and the monoclonal detection antibody was labeled with europium. The one-step binding reaction was stopped by washing after 2 min of incubation, and the fluorescence signal of individual particles was measured. Results: The analytical detection limit (mean of zero calibrator + 3 SD) was 0.00016 mg/L CRP. Clinical samples were diluted 400-fold before assay to cover the CRP concentration range of 0.064–1200 mg/L. The assay correlated well with the Dade Behring N High Sensitivity CRP assay (for 0–10 mg/L, r = 0.969, Sy|x = 0.68, n = 54; for 0–350 mg/L, r = 0.969, Sy|x = 11.7, n = 100). The within- and between-run CVs based on calculated concentrations were, respectively, 9–16% and 14% at 0.11 mg/L, 4.5–12% and 8.2% at 4.2 mg/L, and 3.5–6.3% and 4.4% at 105 mg/L, with a CV <15% at 0.2 mg/L and above. Conclusions: Use of the kinetic microparticle approach combined with time-resolved fluorometry allows ultrasensitive quantification of CRP in whole blood in 2 min with a linear assay range spanning more than four orders of magnitude.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 38 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3