Optimization of Allopurinol Challenge: Sample Purification, Protein Intake Control, and the Use of Orotidine Response as a Discriminative Variable Improve Performance of the Test for Diagnosing Ornithine Carbamoyltransferase Deficiency

Author:

Arranz José A1,Riudor Encarnació1,Rodés Margarita2,Roig Manuel1,Climent Consuelo3,Rubio Vicente3,Sentís Margarita1,Burlina Alberto4

Affiliation:

1. Unitat de Metabolopaties, Hospital Materno-Infantil Vall d’Hebron, 08035 Barcelona, Spain

2. Institut de Bioquímica Clínica, C/Mejia Lequerica s/n, Edifici Helios III, Planta Baixa, Corporació Sanitària, 08028 Barcelona, Spain

3. Instituto de Biomedicina de Valencia (CSIC), C/Jaume Roig 11, 46010 Valencia, Spain

4. Dipartimento di Pediatria, Università di Padova, Via Giustiniani 3, 35128 Padua, Italy

Abstract

Abstract Background: The diagnosis of heterozygosity for X-linked ornithine carbamoyltransferase (OCT) deficiency has usually been based on measurement of the increase of orotate and orotidine excretion after an allopurinol load. We examined the choices of analyte, cutoff, and test conditions to obtain maximal test accuracy. Methods: Urine orotate/orotidine responses to allopurinol load in 37 children (13 OCT-deficient and 24 non-OCT-deficient) and 24 women (7 at risk for carrier status and 17 not related to OCT-deficient children) were analyzed by liquid chromatography after sample purification by anion-exchange chromatography. Diagnostic accuracy was evaluated by nonparametric ROC curves. Results: Sample purification was necessary to prevent interferences. Orotate and orotidine excretion increased with increased protein intake during the test. At a cutoff of 8 mmol orotidine/mol creatinine, sensitivity was 1.0 and specificity was 0.92 in mild forms of OCT deficiency. Results in monoplex carrier women may differ greatly from those expected because of the genetics of this deficiency. Conclusions: Standardization of protein intake is required in the allopurinol loading test. A negative response in the face of clinical suspicion should be followed with a repeat test during a protein intake not <2.5 g · kg−1 · day−1. Measurements of orotidine provide better clinical sensitivity than measurements of orotate.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3