Cross-correlation of cyclosporine concentrations and biochemical measures of kidney and liver function in heart and heart-lung transplant recipients

Author:

Trull A1,Hue K1,Tan K1,Gore S1,Whitewood S1,Smyth R1,Scott J1,Price C1,Wallwork J1

Affiliation:

1. Department of Clinical Biochemistry, Addenbrooke's Hospital, Cambridge, U.K

Abstract

Abstract Cross-correlation of cyclosporine concentrations with results of biochemical tests of renal and liver function, measured during the first three months post-operatively, was carried out retrospectively in 24 heart and eight heart-lung transplant recipients to assess the temporal relationship between cyclosporine treatment and the development of possible toxic side-effects. We found a statistically significant negative correlation (95% confidence interval of the mean correlation coefficient did not overlap zero) between the five-day mean concentration of cyclosporine in whole blood (but not plasma) as measured with nonselective (NSRIA) and selective radioimmunoassays (SRIA) and the mean reciprocal creatinine concentration measured in the subsequent five days. In 15 of 32 (47%) patients the negative correlation coefficient exceeded 0.7 (high susceptibility), whereas in 11 of 32 (34%) it was between 0.5 and 0.7 (medium susceptibility), and in only six of 32 (19%) was it less than 0.3 (low susceptibility). We found no consistent correlations between cyclosporine measurements and results of other renal-function tests or liver-function tests. This suggests that therapeutic doses of the drug are not hepatotoxic in most patients. There was, however, a significantly correlated decrease in the NSRIA/SRIA ratio and in serum bilirubin concentration with time post-operatively, reflecting improvement in hepatic function and clearance of the cyclosporine metabolites that are detected by NSRIA. Assays of cyclosporine in whole blood, but not in plasma, are of value in anticipating changes in renal function after heart and heart-lung transplantation.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3