Assessing the Quality of Metagenomic Next-Generation Sequencing for Pathogen Detection in Lower Respiratory Infections

Author:

Diao Zhenli123,Zhang Yuanfeng123,Chen Yuqing123,Han Yanxi13,Chang Lu123,Ma Yu123,Feng Lei123,Huang Tao123,Zhang Rui123,Li Jinming123

Affiliation:

1. National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology , Beijing , People’s Republic of China

2. National Center for Clinical Laboratories, Chinese Academy of Medical Sciences & Peking Union Medical College , Beijing , People’s Republic of China

3. Beijing Engineering Research Center of Laboratory Medicine, Beijing Hospital , Beijing , People’s Republic of China

Abstract

Abstract Background Laboratory-developed metagenomic next-generation sequencing (mNGS) assays are increasingly being used for the diagnosis of infectious disease. To ensure comparable results and advance the quality control for the mNGS assay, we initiated a large-scale multicenter quality assessment to scrutinize the ability of mNGS to detect pathogens in lower respiratory infections. Methods A reference panel containing artificial microbial communities and real clinical samples was used to assess the performance of 122 laboratories. We comprehensively evaluated the reliability, the source of false-positive and false-negative microbes, as well as the ability to interpret the results. Results A wide variety of weighted F1-scores was observed across 122 participants, with a range from 0.20 to 0.97. The majority of false positive microbes (68.56%, 399/582) were introduced from “wet lab.” The loss of microbial sequence during wet labs was the chief cause (76.18%, 275/361) of false-negative errors. When the human context is 2 × 105 copies/mL, most DNA and RNA viruses at titers above 104 copies/mL could be detected by >80% of the participants, while >90% of the laboratories could detect bacteria and fungi at titers lower than 103 copies/mL. A total of 10.66% (13/122) to 38.52% (47/122) of the participants could detect the target pathogens but failed to reach a correct etiological diagnosis. Conclusions This study clarified the sources of false-positive and false-negative results and evaluated the performance of interpreting the results. This study was valuable for clinical mNGS laboratories to improve method development, avoid erroneous results being reported, and implement regulatory quality controls in the clinic.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3