Bleomycin-detectable Iron Assay for Non-Transferrin-bound Iron in Hematologic Malignancies

Author:

von Bonsdorff Leni1,Lindeberg Enni1,Sahlstedt Leila2,Lehto Jari3,Parkkinen Jaakko1

Affiliation:

1. Finnish Red Cross Blood Transfusion Service, Kivihaantie 7, FIN-00310 Helsinki, Finland

2. Department of Medicine, PO Box 340, Helsinki University Central Hospital, FIN-00029 Helsinki, Finland

3. Department of Public Health, PO Box 41, University of Helsinki, FIN-00014 Helsinki, Finland

Abstract

AbstractBackground: A microwell modification of the bleomycin assay for determining non-transferrin-bound iron (NTBI) was evaluated and compared with a chelation method.Methods: The bleomycin assay reagent and sample volumes were halved, and measurements were done in microwell plates. Samples from patients treated for hematologic malignancies were studied. The chelation method was based on mobilization of NTBI with a chelator and measurement of the ultrafiltered iron-chelator complex. NTBI results were also compared with transferrin saturation and the distribution of transferrin iron forms by urea-polyacrylamide gel electrophoresis.Results: The bleomycin assay intraassay imprecision (CV) was 7.7% and 8.2% and the interassay imprecision was 18% and 9.8% for a low (0.2 μmol/L) and a high (1.5 μmol/L) control, respectively. Hemolysis increased measured NTBI. A detection limit of 0.1 μmol/L was established based on the interference of nonvisible hemolysis and on accuracy studies. In patient samples, NTBI exceeded the detection limits only when transferrin saturation was >80%. Compared with the chelation method, the bleomycin assay gave clearly lower NTBI concentrations. The chelation method also gave positive results at <80% transferrin saturation. The recovery of iron added as ferric nitrilotriacetate to serum was 33% by the bleomycin assay and 64% by the chelation assay.Conclusions: The microwell version of the bleomycin assay is reproducible. When hemolyzed samples were excluded, bleomycin-detectable iron was found only when the transferrin saturation was >80%, suggesting high specificity. Bleomycin-detectable iron constitutes only a portion of the NTBI measured by the chelation method.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 42 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Iron Load Toxicity in Medicine: From Molecular and Cellular Aspects to Clinical Implications;International Journal of Molecular Sciences;2023-08-18

2. Iron-Induced Oxidative Stress in Human Diseases;Cells;2022-07-08

3. Non-transferrin bound iron;Clinica Chimica Acta;2022-06

4. Iron in infection and immunity;Molecular Aspects of Medicine;2020-10

5. Iron overload: Effects on cellular biochemistry;Clinica Chimica Acta;2020-05

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3