Comparison of ELISAs for Opiates, Methamphetamine, Cocaine Metabolite, Benzodiazepines, Phencyclidine, and Cannabinoids in Whole Blood and Urine

Author:

Kerrigan Sarah1,Phillips Jr William H1

Affiliation:

1. California Department of Justice, Bureau of Forensic Services, Toxicology Laboratory, 4949 Broadway, Sacramento, CA 95820

Abstract

Abstract Background: ELISAs are widely utilized in forensic drug analysis. A comparative assessment of microtiter plate assays for the detection of six common classes of drug in blood and urine is described. Methods: ELISAs for opiates, methamphetamine, benzodiazepines, cocaine metabolite, phencyclidine (PCP), and tetrahydrocannabinol (THC) metabolite were evaluated in a side-by-side study. The analytical performance of 12 commercially available ELISAs was determined in terms of binding characteristics, dose–response curves, limits of detection, sensitivity, intra- and interassay imprecision, and lot-to-lot reproducibility. Assay performance was also compared using 855 forensic casework samples. Results: Detection limits in whole blood for morphine, d-methamphetamine, nordiazepam, benzoylecgonine, nordiazepam, PCP, and l-11-nor-9-carboxy-Δ9-THC were 3, 2, <4, 5, 25, and 3 μg/L, respectively, for the STC ELISAs. Corresponding detection limits for Immunalysis ELISAs were <1, <2, <4, 5, <1, and 1 μg/L, respectively. Intraassay CVs (n = 8) at the immunoassay cutoff concentrations were 4.1–5.6% and 3.5–11% for STC and Immunalysis ELISAs, respectively. Corresponding interassay CVs were 3.1–10% and 6.5–20%. Of the 855 casework samples, there were a total of 92 discordant results (44 cannabinoid, 15 opiate, 15 methamphetamine, 11 benzodiazepine, and 7 cocaine metabolite). Gas chromatography–mass spectrometry analysis indicated a total of three unconfirmed positive results for Immunalysis assays and one unconfirmed positive for STC assays. Conclusions: A comparative assessment of drugs-of-abuse assays from two manufacturers indicated some key differences in analytical performance. Overall, Immunalysis assays offered superior binding characteristics and detection limits, whereas STC assays offered improved overall precision and lot-to-lot reproducibility.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3