Improved Measurement of Erythrocyte Volume Distribution by Aperture-Counter Signal Analysis

Author:

Waterman Cleveland S1,Atkinson Earl E1,Wilkins Bert1,Fischer Craig L1,Kimzey Steve L1

Affiliation:

1. Department of Chemical Engineering, Louisiana State University, Baton Rouge, La. 70803 (Waterman, Atkinson, Wilkins); NASA Johnson Spaceflight Center, Houston, Tex. 77058 (Kimzey); Eisenhower Medical Center, Palm Desert, Calif. 99260 (Fischer)

Abstract

Abstract In aperture counters, particles in fluid suspension flow through a small orifice or aperture, causing a change in the electrical resistance of the aperture. This change is sensed by an external electronic circuit and translated into a voltage pulse, the signal height of which is proportional to the volume of the particle in the aperture. These signal pulses are collated into a spectrum of pulse heights by a multichannel pulse-height analyzer. The channel number (voltage increment) spectrum is proportional to the volume distribution of the particles sensed. A problem is that pulse height not only depends on cell volume, but also on the orientation and shape of the particle sensed and the current density along the path taken by the particle through the aperture. Uneven current density exists, primarily at the aperture entrance and exit, close to the wall. Orientation and shape of particles are altered near the wall by the unbalanced shear forces there. Toward the center of the aperture, the shear forces act so as not to induce continuous change in the orientation of the particles sensed. Thus introduction into the pulse-height spectrum of pulses that do not show a good proportionality to volume is primarily caused by particles that are traveling near the aperture wall. Residence time in the aperture for a particle traveling near the wall will be longer than that for a particle traveling down the center of the aperture, because of the smaller fluid velocity near the wall. Duration of the signal pulse created by a particle traveling near the wall will be correspondingly greater. We discuss an electronic filter to remove from the pulse-height spectrum those pulses that appear to result from particles traveling near the wall and the effect of the filter on the measured signal height and hence the volume distribution of erythrocytes. Use of this technique to characterize erythrocytes by volume distribution is described.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3