Efficiency of Two Different Nine-Loci Short Tandem Repeat Systems for DNA Typing Purposes

Author:

Sacchetti Lucia1,Calcagno Giuseppe1,Coto Iolanda1,Tinto Nadia2,Vuttariello Emilia2,Salvatore Francesco1

Affiliation:

1. Dipartimento di Biochimica e Biotecnologie Mediche, Università degli Studi di Napoli “Federico II”, 80131 Napoli, Italy

2. CEINGE-Biotecnologie Avanzate; via S. Pansini 5, 80131 Napoli, Italy

Abstract

Abstract Background: Genotyping based on short tandem repeat (STR) regions is widely used in human identification and parentage testing, in gene mapping studies, and as an approach to studies on the etiopathogenesis and diagnosis of hereditary diseases. We wished to study a new analytical approach that uses capillary electrophoresis and multicolor fluorescence in place of slab gel electrophoresis. Methods: We evaluated the efficiency for parentage and forensic purposes of the AmpFLSTR Profiler PlusTM typing kit that is used with the ABI Prism 310 Genetic Analyzer (System-2 STR), and that of a widely used panel of nine STRs analyzed with conventional slab-gel electrophoresis followed by radioactive detection (System-1 STR). System-2 STR, based on automated capillary electrophoresis and automated sizing of the alleles by Genotyper 2.0 software, was used to determine the allele frequency of the nine loci in 157 Caucasian subjects from southern Italy. On the basis of the data obtained, we submitted 40 trios to parentage testing. Results: A higher median probability of paternity attribution and power of exclusion were obtained with System-2 STR vs System-1 STR: respectively, 99.99% and 99.95% (P <0.05) for attribution; and five and four excluding loci (P <0.05) for exclusion. The most informative and highly discriminating loci were D18S51, D21S11, and FGA. The combined probability of matching-by-chance for all nine STRs was 1.36 × 10−12 for System-2 compared with 1.11 × 10−7 obtained with the other system. The internal standard and allelic ladder of the System-2 STR facilitated accurate and precise genotyping; furthermore, System-2 STR and was faster than the conventional System-1 STR. Conclusions: The System-2 STR allows rapid testing with higher probabilities of attribution and a higher power of exclusion than with the comparison method with slab-gel electrophoresis.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3