Affiliation:
1. Department of Pathology, Southport General Infirmary, U.K
Abstract
Abstract
The performance of a modified commercial (Diagnostic Products Corp.) assay for free triiodothyronine in serum was evaluated, and its diagnostic value was compared with two other methods for free triiodothyronine estimation in euthyroid subjects and in patients with thyroid dysfunction. No advantage was demonstrated for the modified assay as an index of thyroid status. In conditions involving thyroxin-binding globulin excess the modified assay produced misleading results more frequently than did the comparison methods.
Publisher
Oxford University Press (OUP)
Subject
Biochemistry (medical),Clinical Biochemistry
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献