Assay instrument-dependent matrix effects in standardization of cholesterol measurements

Author:

Waymack P P1,Miller W G1,Myers G L1

Affiliation:

1. Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30333

Abstract

Abstract Human serum-based frozen reference materials have been used by the Centers for Disease Control and Prevention (CDC)-National Heart, Lung and Blood Institute Lipid Standardization Program to improve the precision and accuracy of blood cholesterol measurements. Occasionally, laboratories in the program have had problems obtaining results for patients' fresh serum samples equivalent to those obtained with frozen CDC standardization pools. This incompatibility of sample, reagent, instrument, and assay characteristics has been labeled broadly as a "matrix effect," which usually is attributed to unknown characteristics of the processed pool material. In this study we showed that a large negative bias obtained with CDC pools was attributable to use of the sample blank mode on the Cobas-Bio analyzer. However, under the same conditions, fresh patients' serum samples were analyzed accurately. The use of a blank absorbance immediately after mixing sample and reagents (the "autoblank" mode) allowed the instrument to accurately analyze both fresh serum samples and CDC standardization pools and thus allowed the documentation of traceability of the cholesterol measurements to the National Reference System for Cholesterol.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 10 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. The evolving role of commutability in metrological traceability;Clinica Chimica Acta;2021-03

2. Determination of cholesterol in blood. Part 3;Review Journal of Chemistry;2016-07

3. Investigation of cholesterol bias due to a matrix effect of external quality assurance samples: how true is your cholesterol method?;Annals of Clinical Biochemistry: International Journal of Laboratory Medicine;2012-09-27

4. Quality Control;Henry's Clinical Diagnosis and Management by Laboratory Methods;2011

5. Introduction to standardization of laboratory results;Steroids;2008-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3