Abstract Background: Proficiency testing (PT) provides a measure of the effectiveness of laboratory quality assurance programs. Test reports are released from processes that the laboratory judges to be in conformance with quality specifications; an evaluation of unsatisfactory performance (UNSAT) by a PT provider is an unexpected outcome for the laboratory. An understanding of the root cause(s) of testing errors provides an opportunity for the continuous improvement of laboratory services. Methods: We used participant data from the New York State Department of Health PT program to characterize the quality of testing in the toxicology specialty. Outcomes from laboratory investigations into causes of UNSAT and information on quality control practices collected from all program participants were used to identify the root causes of error. Results: Two classes of error were encountered: spurious test results caused by lapses in standard operating procedures and instrument malfunctions (300 per million assays) and common-cause analytic error (7000 per million assays or 0.7% rate of UNSAT). Causes of spurious results included inaccurate mathematical correction for specimen dilution, misinterpretation of instrument codes, and instrument sampling errors. Calibration drift was most frequently cited as the common-cause analytic error. Approximately one-half of the laboratories used an allowable error for the quality control of analytical systems that exceeded the threshold error specified by manufacturers for stable instrument performance. Conclusions: The causes of spurious results suggest the need for ongoing competency testing of analysts where analyst intervention is required in an otherwise automated process, and for continued diligence in mistake-proofing instrument design. The intrinsic quality of laboratory testing is unlikely to improve until the allowable error in quality control is consistent with manufacturer specifications for stable system performance.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3