New techniques for ion-selective measurements of ionized calcium in serum after pH adjustment of aerobically handled sera.

Author:

Schwartz H D

Abstract

Abstract I report further experience in measuring ionized calcium (Ca2+) with the AMT Electron System and its serum standards and solid-state, dip, calcium-selective electrodes. With this system, serum pH can be adjusted with CO2 gas and Ca2+ and pH simultaneously measured; when 5.2% CO2 (40 mm pco2) is used for sample equilibration, the standard bicarbonate concentration is also provided. I measured serum Ca2+ as a function of pH between pH 7.0 and 9.0 and found the relationship to be reproducible, with no evidence of irreversible complexing of Ca2+. When the pH of aerobically exposed, mailed sera was restored to the original values, their values for Ca2+ were the same as for the fresh sera. Measurement of Ca2+ in routinely (aerobically) handled sera after pH restoration with CO2 gas was therefore validated, both samples from within an institution and mailed specimens. Standardization to pH 7.40 is recommended for routine measurements, is generally more accurate than use of heparin or quasianaerobic techniques, and is a practical approach. In patients with possible uncompensated acid-base disturbance (which may be indicated by an abnormal standard bicarbonate concentration if not suspected clinically), patient pH should be measured independently as part of the usual strict, anaerobic blood-gas-analysis procedures. Abnormal patient pH must be considered in the interpretation of Ca2+ results determined at pH 7.40 which are borderline or slightly abnormal; most accurately, Ca2+ may be measured in the separated sera at the previously determined patient pH value. Studies of aqueous solutions with the currently used Ca2+ electrodes showed a selectivity coefficient (the constant which relates the activity of an interfering ion to the activity of calcium that would contribute the same emf) KNa=0.0031 +/- 0.0003 (SE) and KMg=0.046 +/- 0.004 (SE). At physiological concentrations of Ca2+, physiologically encountered variation in Na+ is of no significance in resulting Ca2+, but extreme variation in Mg2+ may cause an error of approximately 1%.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 24 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3