Establishing Pragmatic Analytical Performance Specifications for Blood Beta-Hydroxybutyrate Testing

Author:

Kilpatrick Eric S1,Butler Alexandra E2,Atkin Stephen L2,Sacks David B3ORCID

Affiliation:

1. Department of Clinical Biochemistry, Manchester Royal Infirmary , Manchester , United Kingdom

2. Department of Postgraduate Studies and Research, Royal College of Surgeons in Ireland , Busaiteen , Bahrain

3. Department of Laboratory Medicine, National Institute of Health , Bethesda, MD , United States

Abstract

Abstract Background Currently, no authoritative guidelines exist recommending the analytical performance specification (APS) of blood beta-hydroxybutyrate (BOHB) testing in order to meet the clinical needs of patients. This study has applied existing diabetic ketoacidosis (DKA) BOHB diagnostic thresholds and the recommended rates of fall in BOHB concentrations during DKA treatment to establish pragmatic APSs for BOHB testing. Methods Required analytical performance was based on 2 clinical requirements: (a) to reliably distinguish between non-adjacent DKA BOHB diagnostic categories of <0.6, 0.6 to 1.5, 1.6 to 2.9, and ≥3 mmol/L, and (b) to be assured that a measured 0.5 mmol/L reduction in BOHB indicates the true concentration is at least falling (meaning >0 mmol/L decline). Results An analytical coefficient of variation (CV) of <21.5% could reliably distinguish all non-adjacent diagnostic categories with >99% certainty, assuming zero bias. In contrast, within-day CVs of 4.9%, 7.0%, and 9.1% at 3 mmol/L BOHB were required to assure truly falling ketone concentrations with 99% (optimal), 95% (desirable), and 90% (minimal) probability, respectively. These CVs are larger at lower BOHB concentrations and smaller at higher concentrations. Conclusions Reliable tracking of changes in BOHB during DKA treatment largely drives the requirement for analytical performance. These data can be used to guide minimal, desirable, and optimal performance targets for BOHB meters and laboratory assays.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Setting analytical performance specifications for copeptin-based testing;Clinical Chemistry and Laboratory Medicine (CCLM);2024-06-12

2. Outcome-based analytical performance specifications: current status and future challenges;Clinical Chemistry and Laboratory Medicine (CCLM);2024-06-06