Author:
Andreolini F,Borra C,Caccamo F,Di Corcia A,Nicoletti I,Samperi R,Improta F
Abstract
Abstract
We report a method for measuring estriol and its intact conjugates in urine, serum, and amniotic fluid. A single assay can be done within about 50 min, eight samples assayed in less than 5 h. A 70-microL urine sample is diluted and the estriol conjugates are adsorbed from it onto graphitized carbon black (Carbopack B, Supelco). After two washings, the analytes are desorbed with chloroform/methanol (60/40, by vol) containing tetrapropylammonium bromide. After solvent evaporation, the residue is redissolved in 100 microL of water/acetonitrile and 20 microL is injected into the chromatograph. Or 1 mL of serum or 0.5 mL of amniotic fluid is deproteinized with cold methanol, then passed through the Carbopack column. After three washings, the estriol and its conjugates are desorbed and treated as for urine. Mean analytical recoveries of the analytes in any of these body fluids were within about 92-98%, except for estriol-3-sulfate-16 alpha-glucuronide in serum (mean recovery 88.3%). The limit of sensitivity is well below the concentrations of clinical interest, and the method is not susceptible to substantial interferences.
Publisher
Oxford University Press (OUP)
Subject
Biochemistry, medical,Clinical Biochemistry
Cited by
14 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献