Determination of Anti-Acetylcholine Receptor Antibodies in Myasthenic Patients by Use of Time-resolved Fluorescence

Author:

Říčný Jan1,Šimková Libuše2,Vincent Angela3

Affiliation:

1. Institute of Physiology, Academy of Sciences of Czech Republic, Vídeòská 1083, 142 20 Prague, Czech Republic

2. Neurologic Clinic, 1st Medical Faculty of Charles University, Kateøinská 30, 120 00 Prague, Czech Republic

3. Neurosciences Group, Department of Clinical Neurology, Institute of Molecular Medicine, John Radcliffe Hospital, Oxford OX3 9DU, United Kingdom

Abstract

AbstractBackground: Autoantibodies against nicotinic acetylcholine receptor (nAChR) in myasthenia gravis (MG) patients are usually detected by radioimmunoprecipitation assays using extracted acetylcholine receptors labeled irreversibly with 125I-α-bungarotoxin (α-BuTx). To provide a nonradioactive immunoassay, we established an assay using nAChRs labeled with Eu3+-α-cobratoxin (α-CTx).Methods: We derivatized α-CTx with a diethylenetriaminepentaacetate moiety and formed a complex with Eu3+. The complex was purified by HPLC, and the fractions were tested for binding to Torpedo and human nAChRs. The most active fractions were used to label nAChRs for the immunoprecipitation assay, and the bound Eu3+ was quantified by time-resolved fluorescence.Results: Eu3+-labeled α-CTx competed with 125I-α-BuTx for binding to Torpedo nAChRs and saturated the binding sites of human nAChRs, with a Kd of 7.2 × 10−9 mol/L. Results of the immunoassay performed with Eu3+-labeled α-CTx were similar to those obtained with 125I-α-BuTx, with a slightly higher limit of detection [0.3 nmol/L (n = 6) vs ∼0.1 nmol/L for isotopic assay]. None of 34 negative sera tested (16 healthy controls, 10 patients with nonmyasthenia-related disease, 8 patients seronegative for MG) gave a value >0.3 nmol/L. Of the 35 positive myasthenic sera (with antibody values, previously determined by isotopic assay, of 0.4–1290 nmol/L) compared in the two assays, 32 tested positive with the Eu3+ assay. Linear regression analysis yielded the equation: y = 1.035x − 0.013 nmol/L; Sy|x = 0.172 nmol/L; r2 = 0.977.Conclusions: The new time-resolved fluorescence method for quantification of antibodies to nAChRs in MG patients provides a performance similar to that of the widely used isotopic assay and could be used in laboratories with restricted use of isotopes.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3