Standardization of Cardiac Troponin I Assays: Round Robin of Ten Candidate Reference Materials

Author:

Christenson Robert H1,Duh Show Hong1,Apple Fred S2,Bodor Geza S3,Bunk David M4,Dalluge Joseph4,Panteghini Mauro5,Potter James D6,Welch Michael J4,Wu Alan H B7,Kahn Stephen E8

Affiliation:

1. Department of Pathology, University of Maryland School of Medicine, 22 S. Greene St., Baltimore, MD 21201

2. Department of Laboratory Medicine and Pathology, Hennepin County Medical Center, and the University of Minnesota School of Medicine, Minneapolis, MN 55415

3. Denver Health Medical Center, Denver, CO 80204

4. Analytical Chemistry Division, National Institute of Standards and Technology, Gaithersburg, MD 20899

5. Clinical Chemistry Laboratory, Azienda Ospedaliera ’Spedali Civili, 25125 Brescia, Italy

6. Department of Pharmacology, University of Miami School of Medicine, Miami, FL 33101

7. Department of Pathology and Laboratory Medicine, Hartford Hospital, Hartford, CT 06102

8. Departments of Pathology, Cell Biology, Neurobiology, and Anatomy, Loyola University Medical Center, Maywood, IL 60153

Abstract

AbstractBackground: Cardiac troponin I (cTnI) results vary 100-fold among assays. As a step toward standardization, we examined the performance of 10 candidate reference materials (cRMs) in dilution studies with 13 cTnI measurement systems.Methods: Solutions of 10 cTnI cRMs, each characterized by NIST, were shipped to the manufacturers of 13 cTnI measurement systems. Manufacturers used their respective diluents to prepare each cRM in cTnI concentrations of 1, 10, 25, and 50 μg/L. For the purpose of ranking the cRMs, the deviation of each cTnI measurement from the expected response was assessed after normalization with the 10 μg/L cTnI solution. Normalized deviations were examined in five formats. Parameters from linear regression analysis of the measured cTnI vs expected values were also used to rank performance of the cRMs.Results: The three cRMs demonstrating the best overall rankings were complexes of troponins C, I, and T. The matrices for these three cRMs values differed; one was reconstituted directly from the lyophilized form submitted by the supplier; one was submitted in liquid form, lyophilized at NIST, and subsequently reconstituted; and the third was evaluated in the liquid form received from the supplier. The cRM demonstrating the fourth best performance was a binary complex of troponins C and I supplied in lyophilized form and reconstituted before distribution.Conclusions: The cRMs demonstrating the best performance characteristics in 13 cTnI analytical systems will be included in subsequent activities of the cTnI Standardization Committee of the AACC.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3