Analytical Quality of Near-Patient Blood Cholesterol and Glucose Determinations

Author:

du Plessis Marita1,Ubbink Johan B1,Vermaak W J Hayward1

Affiliation:

1. Department of Chemical Pathology, University of Pretoria, Institute of Pathology, PO Box 2034, Pretoria 0001, South Africa

Abstract

Abstract Background: Screening for diabetes and hypercholesterolemia is widely advocated, and extra-laboratory testing could play a major role in cost-effective population screening. We wished to assess the analytical quality and interchangeability of capillary blood cholesterol and glucose assays as performed on near-patient devices in pharmacies in Pretoria, South Africa. Methods: Accuracy of near-patient and laboratory analyzers was assessed by analyses of human-serum-based reference material. To assess interchangeability in routine use, six volunteers visited each of 12 randomly selected pharmacies consecutively during a 3-week period to have their fasting blood glucose and cholesterol concentrations determined. For comparison purposes, a similar procedure was followed to evaluate the eight clinical chemistry laboratories servicing Pretoria and surroundings. Results: The analytical performances in our laboratory of a single point-of-care instrument and of a laboratory analyzer compared well. Nevertheless, between-pharmacy analytical variation was larger than between-laboratory variation (11% vs 6.1% for cholesterol; 10% vs 7.6% for glucose). For glucose measurements, near-patient testing in pharmacies demonstrated a bias of −48.1% to 16.2%, whereas bias for laboratory measurements was −1.0% to 7.4%. Cholesterol assays showed a bias of −5.6% to 16.6% in pharmacies compared with −10.6% to 3.7% in laboratories. The percentage of closeness to the homeostatic set point for a single glucose and cholesterol determination done in any pharmacy was 24.6% and 23.6%, respectively. The corresponding values for laboratories were 16.9% and 15.6%, respectively. Conclusions: Although modern point-of-care instruments allow high-quality blood analyses under ideal conditions, performance goals often are not achieved in practice as indicated by a higher uncertainty of cholesterol and glucose blood results when determined in pharmacies. Nonuniformity of calibration procedures, deficiencies in training, a lack of internal quality control, and the absence of an external quality assessment program may all contribute to the current state of affairs.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 20 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3