Flow Cytometric Assessment of LDL Ligand Function for Detection of Heterozygous Familial Defective Apolipoprotein B-100

Author:

Raungaard Bent1,Heath Finn2,Hansen Peter Steen2,Brorholt-Petersen Jens Uffe1,Jensen Henrik Kjærulf2,Færgeman Ole1

Affiliation:

1. Department of Internal Medicine and Cardiology, Aarhus Amtssygehus University Hospital, Tage Hansens Gade 2, DK-8000 Aarhus C, Denmark

2. Department of Cardiology, Skejby Sygehus University Hospital, DK-8200 Aarhus N, Denmark

Abstract

AbstractBackground: Familial defective apolipoprotein (apo) B-100 (FDB) is caused by a mutation in the apoB gene and characterized by decreased binding of LDL to LDL receptors because of reduced function of the apoB-100 ligand. FDB may be associated with severe hypercholesterolemia and cannot always be distinguished from familial hypercholesterolemia phenotypically.Methods: We used a fluorescence flow cytometry assay with Epstein-Barr virus-transformed lymphocytes to detect reduced LDL ligand function by competitive binding with fluorescently conjugated LDL (DiI-LDL). The assay was tested and validated using LDL from patients heterozygous for the Arg3500-Gln mutation and their first-degree relatives. Knowing the actual apoB genotype of patients and relatives allowed us to assess the ability of the assay to predict the results of DNA analysis. The results were compared to measurements of LDL ligand function in unrelated healthy control subjects to characterize functionally the Arg3500-Gln mutation.Results: Fluorescence was significantly increased in cells incubated with DiI-LDL in competition with unlabeled LDL from FDBR3500Q heterozygotes compared with cells incubated with DiI-LDL in competition with unlabeled LDL from relatives or unrelated healthy control subjects. Thus, patients heterozygous for the Arg3500-Gln mutation had significantly reduced LDL ligand function. The binding affinity of LDL from FDBR3500Q heterozygotes was 32% of that in non-FDB relatives and healthy controls. The assay had a diagnostic sensitivity of 0.95 and diagnostic specificity of 0.89.Conclusions: The diagnostic accuracy of the assay was too low to allow reliable diagnosis of individual cases of heterozygous FDBR3500Q. However, fluorescence flow cytometry may supplement genetic identification of FDB and functionally characterize gene mutations associated with major reductions in LDL ligand function.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3