Rapid Liquid Chromatography-Tandem Mass Spectrometry Method for Routine Analysis of Cyclosporin A Over an Extended Concentration Range

Author:

Keevil Brian G1,Tierney David P1,Cooper Donald P2,Morris Michael R2

Affiliation:

1. Department of Clinical Biochemistry, Wythenshawe Hospital, Manchester M23 9LT, United Kingdom

2. Clinical Applications Group, Micromass, UK Ltd, Manchester M23 9LZ, United Kingdom

Abstract

Abstract Background: Cyclosporin A (CsA) is commonly measured by immunoassay techniques that have a limited analytical range. The consequence of this is that low CsA concentrations that may be clinically significant are difficult to measure and that high concentrations require sample dilution, which introduces error and increases cost. More specific assays, such as HPLC, do not have the required turnaround times for busy transplant clinics. Methods: CsA was measured in whole blood from 180 cardiac and lung transplant recipients by a liquid chromatography-tandem mass spectrometry (MS) assay, and the results were compared with the Dade Behring Emit assay. Proteins were precipitated with acetonitrile containing ascomycin as internal standard. We used isocratic elution on a Supelco CN column (33 × 3.0 mm; 3- μm bead size) with a mobile phase of 65% aqueous acetonitrile containing ammonium acetate (2 mmol/L) and formic acid (1 g/L), at a flow rate of 0.5 mL/min, with a sample injection volume of 6 μL. We used positive-ion electrospray MS to monitor the ammonium adducts of the compounds of interest decomposing under controlled conditions to the most dominant fragments of the individual molecules. Calibration curves used linear least-squares regression with 1/x weighting. Results: Maximum sensitivity was obtained by monitoring fragmentation of the ammonium adducts m/z 1220→m/z 1203 for CsA and m/z 809→m/z 765 for ascomycin. Sample throughput, including preparation time, was 30 samples in 1.5 h with an injection-to-injection cycle time of 1.5 min. The calibration curve was linear to 5000 μg/L, with a detection limit of 0.03 μg/L and a limit of quantification of 1 μg/L. Regression analysis [tandem MS method (y) and Emit assay (x)] yielded a slope of 1.09 (± 0.03), an intercept of 6.2 (± 4.5) μg/L, and Sy|x = 27 μg/L. Conclusions: Tandem MS assay is a realistic alternative to immunoassay for the routine monitoring of CsA in transplant recipients. Its wide dynamic range has utility for pharmacokinetic studies of CsA.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3