Detection of intracellular antigens by flow cytometry: comparison of two chemical methods and microwave heating

Author:

Millard Isabelle1,Degrave Etienne2,Philippe Marianne1,Gala Jean-Luc12

Affiliation:

1. Cliniques Universitaires Saint-Luc, Université Catholique de Louvain, Clinical Biochemistry Department, Clos-Chapelle-aux-Champs, 30-UCL 30.46, 1200 Brussels, Belgium

2. Scientific Section of the Medical Staff, Belgium Armed Forces, Queen Astrid Military Hospital, Rue Bruyn, 2, 1120 Brussels, Belgium

Abstract

Abstract Detection of intracellular antigens by flow cytometry requires effective fixation and permeabilization of the cell membrane. This study compares three fixation/permeabilization techniques: two commercial chemical reagents, the ORTHOPermeaFixTM (OPF) and the FIX&PERM Cell Permeabilization Kit® (F&P), and a novel method based on microwave heating (MWH). They have been applied to the detection of two nuclear (p53 and rb/p105) and two cytoplasmic (bcl-2 and mdr-1/gp-170) antigens, using positive- and negative-control cell lines and peripheral blood mononuclear cells. Western blotting was performed as a control of protein expression. For the four antigens assessed, cellular morphology, discrimination between intact cells and debris, percentage of positive cells, and mean fluorescence intensity were examined. For this last parameter, the assessment of the MWH technique was performed using SD and a graphical approach inspired by the concepts described by Bland and Altman (Lancet 1986;346:1085–7) as well as Petersen et al. (Clin Chem 1997;43:2039–46). The statistical analysis shows that MWH is comparable to the commercial methods and that its reproducibility is also equivalent to OPF and F&P. As assessed for some of the most clinically relevant intracytoplasmic and intranuclear antigens, the MWH method appears to be a valuable and inexpensive alternative. It is worth noting that, unlike commercial reagents, MWH altered surface antigens. Interestingly, this feature, which would prevent cell selection on the basis of combined membrane and intracellular epitopes, is associated with a decrease of nonspecific background fluorescence.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3