A-002 The Prevalence of the High Sensitivity Cardiac Troponin I Outlier and False Positivity Rates on Beckman Coulter Access DxI

Author:

Li X1,Bryksin J1

Affiliation:

1. Emory University , Atlanta, GA

Abstract

Abstract Background The false positive elevation in high sensitivity cardiac troponin I (hsTnI) can be triggered by many factors, for example, fibrin clots, heterophile antibodies, or other sources of troponin interferences. These interferences lead to inaccurate hsTnI results. These inaccurate results described in the literature as the “outliers”. Published studies use statistical tools to identify the outliers based on the discrepancies between the two repeat values. Depending on the instrument platform and the study design, the outlier rate for the conventional troponin I assay was reported from 0.44% to 1.01% (1, 2). In our laboratory, the false positivity rate for the conventional troponin assay on Beckman Coulter DxI platform was determined as 1% (unpublished data). This study aim was to determine both the statistically and clinically significant outliers for hsTnI assay on the Beckman Coulter Access DxI instrument in the academic medical center clinical laboratory setting. Methods A unique test repeat protocol was created. Two parallel hsTnI measurements are conducted in lithium heparin tubes (BD Vacutainer) on Beckman Coulter DXI 800 systems. When the difference between the two results is greater than 30%, a third repeat is automatically ordered and run after additional centrifugation at a higher relative centrifugal force. The outlier determination is based on assessing the difference between the first two values using previously described statistical analysis tools (1). The clinically significant outlier was determined by counting positive results in the first two runs which are not unconfirmed by the third run, i.e., false positive results. Gender specific cutoffs, 14 ng/L for female and 19 ng/L for male, were applied to identify the positive results. Overall, 2935 patients’ results were evaluated during the study. Results Based on the analysis of the first two repeat runs, out of 2935 samples 16 samples, or 0.54%, were identified as the statistical outliers. 2 out of these 16 outliers, or 12.5%, were negative results. Taking into consideration the third repeat data, 13 out of 2935 samples, or 0.44%, were identified as false positive results. Only 9 out of 13 false positive results, or 69.2%, were identified using the statistical approach above. Conclusion The false positivity rate of hsTnI testing has dropped significantly from 1% to 0.44% in a setting of our laboratory. Our refined repeat protocol approach significantly increases the clinician’s confidences in the hsTnI results by capturing potential false positive results. This approach addresses the outliers at an additional expense like reagents, instrument wear and tear, and labor. Therefore, a more robust methodology is still desired by the industry.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3