Multicenter Technical and Clinical Evaluation of a Fully Automated Enzyme Immunoassay for CA 125

Author:

Kenemans P1,Bon G G1,Kessler A C1,Verstraeten A A1,van Kamp G J1

Affiliation:

1. Department of Obstetrics & Gynecology, Free University Hospital, Amsterdam, The Netherlands

Abstract

Abstract The technical performance and clinical usefulness of the newly developed Enzymun-Test CA 125 (Boehringer Mannheim) was evaluated in a multicenter study. Sera tested were obtained from healthy control subjects (n = 1003) and from patients with benign conditions (379), ovarian cancer (518), or other malignancies (479). Intra- and interassay variability was low at CA 125 concentrations greater than 100 units/mL. Intra- and interassay CVs were respectively less than or equal to 36% and 23% for the low CA 125 concentrations (less than or equal to 35 units/mL) and less than or equal to 15% and 14% for the medium CA 125 concentrations (36- less than or equal to 100 units/mL). Interlaboratory reproducibility of the Enzymun-Test CA 125 was excellent. A strong linear correlation was observed between Enzymun-Test CA 125 and three of four other commercially available assays of CA 125 in serum. Cutoff values of 35 units/mL in three of these other tests corresponded to Enzymun-Test CA 125 values ranging from 27.0 to 42.1 units/mL. In the fourth test, an enzyme immunoassay, a cutoff of 35 units/mL corresponded to Enzymun-Test values ranging from 64.1 to 77.0 units/mL. Discordant, as yet unexplained, results in which Enzymun-Test values were greater than 65 units/mL and Centocor CA 125 immunoradiometric assay results were less than 35 units/mL were found in 15 of 1003 samples (1.5%) of apparently healthy control subjects. Sensitivity and performance of the Enzymun-Test were very similar to those of the Centocor assay for sera from the patients with various benign disorders or malignant diseases. Given its excellent automated technical performance, this new CA 125 serum assay is feasible for monitoring ovarian cancer patients. Test results are interchangeable with those from other laboratories and, in general, with those obtained by most other CA 125 tests.

Publisher

Oxford University Press (OUP)

Subject

Biochemistry (medical),Clinical Biochemistry

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司